background image

WARNING! Some dust particles created by power sanding, sawing, 

grinding, drill and other construction jobs contain chemicals known 

to  cause  cancer,  birth  defects  or  other  reproductive  harm. 

Some 

examples of these chemicals are:

•  Lead from lead-based paints. 

•  Crystalline silica from bricks and cement and other masonry products. 

•  Arsenic and chromium from chemically treated timber.  

Your risk from these exposures varies, depending upon how often you do 

this type of work. To reduce your exposure to these dusts:

•  Work in a well-ventilated.

•  Work with approved protective equipment, such as those dust masks 

that are specially designed to filter microscopic particles.

VIBRATION 

The European Physical Agents (Vibration) Directive has been brought in to help reduce 

hand arm vibration syndrome injuries to power tool users. The directive requires power 

tool manufacturers and suppliers to provide indicative vibration test results to enable 

users to make informed decisions as to the period of time a power tool can be used 

safely on a daily basis and the choice of tool. 

SEE TECHNICAL SPECIFICATIONS IN THE INSTRUCTION MANUAL FOR THE 

VIBRATION LEVELS OF YOUR TOOL.

The declared vibration emission value should be used as a minimum level and should 

be used with the current guidance on vibration. 

Calculating the actual period of the actual period off use can be difficult and the HSE 

website has further information. 

The declared vibration total value has been measured in accordance with EN 62841-1 

and EN 62841-2-4 and may be used for compare one tool with another. 

The declared vibration total value may also be used in a preliminary assessment of 

exposure.

Construction workers are one of the at-risk groups within this because of the dust that 

they breathe: silica dust is not just a nuisance; it is a real risk to your lungs! 

Silica is a natural mineral present in large amounts in things like sand, sandstone and 

granite. It is also commonly found in many construction materials such as concrete and 

mortar. The silica is broken into very fine dust (also known as Respirable Crystalline 

Silica or RCS) during many common tasks such as cutting, drilling and grinding. 

Breathing in very fine particles of crystalline silica can lead to the development of: 

•  lung cancer

•  Silicosis

•  Chronic obstructive pulmonary disease (COPD). 

And breathing in fine particles of wood dust can lead to the development of Asthma. 

The risk of lung disease is linked to people who regularly breathe construction dust 

over a period of time, not on the odd occasion.

To protect the lung, the COSHH Regulations sets a limit on the amount of these dusts 

that you can breathe (called a Workplace Exposure Limit or WEL) when averaged over 

a normal working day. These limits are not a large amount of dust: when compared to 

a penny it is tiny – like a small pinch of salt:

This limit is the legal maximum; the most you can breathe after the right controls have 

been used.

How to reduce the amount of dust?

1.  Reduce the amount of cutting by using the best sizes of building products.

2.  Use a less powerful tool e.g. a block cutter instead of angle grinder.

3.  Using a different method of work altogether – e.g. using a nail gun to direct fasten 

cable trays instead of drilling holes first.

Please always work with approved safety equipment, such as those dust masks that 

specially designed to filter out microscopic particles and use the dust extraction facility 

at all time.

For more information please see the HSE website: 

http://www.hse.gov.uk/construction or http://www.hse.gov.uk/pubns/cis69.pdf

11

10

Содержание 3663602796886

Страница 1: ...ETSS260 EAN 3663602796886 ORIGINAL INSTRUCTIONS MNL_ETSS260_V03_BX220IM 10 8 2020...

Страница 2: ...Safety instructions 7 Product description 14 Assembly 16 Use 20 Care maintenance 22 Guarantee 25 Declaration of conformity 26 2...

Страница 3: ...1 x1 WARNING Please read all safety warnings carefully and be sure that they are fully understood before handling the tool 3 2...

Страница 4: ...Product description 1 4 5 6 7 8a 10a 11a 10 11 11b 12 13 10a 11a 8 9 2 3 A C E 4...

Страница 5: ...A 7 13 B 8a 8a 8 8 7 C D 8 8 13 8a 8 7 13 E F 12 10 6 1 2 5 4...

Страница 6: ...G 1 2 3 G 1 1 2 10a 10a H 6 11 I J 2 1 1 2 11a 11a 11c 11b K 3 2 5 1 2 6...

Страница 7: ...ed grounded power tools Unmodified plugs and matching outlets will reduce risk of electric shock b Avoid body contact with earthed or grounded surfaces such as pipes radiators ranges and refrigerators...

Страница 8: ...action can cause severe injury within a fraction of a second 4 POWER TOOL USE AND CARE a Do not force the power tool Use the correct power tool for your application The correct power tool will do the...

Страница 9: ...t its power cord and plug as well as accessories for damage before each use Do not use the product if it is damaged or shows wear f Double check that the accessories and attachments are properly fixed...

Страница 10: ...tion dust over a period of time not on the odd occasion To protect the lung the COSHH Regulations sets a limit on the amount of these dusts that you can breathe called a Workplace Exposure Limit or WE...

Страница 11: ...hand arm vibration syndrome injuries to power tool users The directive requires power tool manufacturers and suppliers to provide indicative vibration test results to enable users to make informed dec...

Страница 12: ...WARNING Identify safety measures to protect the operator that are based on an estimation of exposure in the actual conditions of use taking account of all parts of the operating cycle such as the tim...

Страница 13: ...going white as well as specific diseases such as carpal tunnel syn drome To reduce this risk when using the product always wear protective gloves and keep your hands warm RESIDUAL RISKS Even if you ar...

Страница 14: ...s marked with are not shown in this overview Please refer to the respective section in the instruction manual Symbols the following symbols and abbreviations Familiarize yourself with them to reduce h...

Страница 15: ...ng label explanation ETSS260 Model number E Erbauer TSS 1 3 Sheet Sander 260 Power Watts r ce th 15 14 The sound emission values have been obtained according to the noise test code given in EN 62841 1...

Страница 16: ...n This also includes suitable personal protective equipment WARNING The product must be fully assembled before operation Do not use a product that is only partly assembled or assembled with damaged pa...

Страница 17: ...inishing cleaning plaster and water stain from wood Only use suitable sanding papers in terms of application and size Do not use papers that are bigger than the base plate of the product Replace worn...

Страница 18: ...rs 8a are now opened and loose Pull out old sanding paper and clean the base plate if applicable Fig B 2 Align the hole pattern of the sanding paper 13 with the one in the base plate 7 to ensure effic...

Страница 19: ...dust extraction outlet 6 Fig F 2 To remove the dust extraction adaptor press both release levers 10a and pull the dust extraction adaptor off Fig G Dust collection box 1 Attach the dust collection bo...

Страница 20: ...tinuous mode 1 Switch the product on by pressing the on off switch 2 and hold it in position 2 Press the lock on button 3 to lock the on off switch 2 3 Release both switches The on off switch 2 is now...

Страница 21: ...t hand grip 1 and with the other hand on the main handle 4 Switch the product on and wait until it runs at full speed before placing it on the workpiece Move the product slowly and steadily over the w...

Страница 22: ...pressure air max 3 bar 4 Check for worn or damaged parts Replace worn parts as necessary or contact an authorised service centre for repair before using the product again Do not use chemical alkaline...

Страница 23: ...ted to the terminal which is marked L or coloured red 13 AMP fuse approved to BS 1362 Brown L Live Cable grip Outer sleeve firmly clamped C o n n e c t Blue to N Neutral WARNING Never connect live or...

Страница 24: ...cribed above 3 Store the product and its accessories in a dark dry frost free well ventilated place 4 Always store the product in a place that is inaccessible to children The ideal stor age temperatur...

Страница 25: ...al This guarantee does not cover defects and damage caused by or resulting from Normal wear and tear Overload misuse or neglect Repairs attempted by anyone other than an authorised agent Cosmetic dama...

Страница 26: ...standard were made EN 62841 1 2015 EN 62841 2 4 2014 2014 30 EU Electromagnetic Compatibility directive References to the following harmonized standard were made EN 55014 1 2017 EN 55014 2 2015 EN 61...

Страница 27: ...directive References to the following harmonized standard were made EN 55014 1 2017 EN 55014 2 2015 EN 61000 3 2 2014 EN 61000 3 3 2013 2011 65 EU EU 2015 863 Restrictions of the Use of Certain Hazard...

Страница 28: ...3 Sheldon Square London W2 6PX United Kingdom www kingfisher com products Kingfisher International Products B V Rapenburgerstraat 175E 1011 VM Amsterdam The Netherlands Distributor www diy com www sc...

Отзывы: