User Manual 

The full manual can be found on USB 

 

era

vap: Vapor Pressure Tester 

 

 

 

 

 

 

era

lytics® GmbH 

|

 Lohnergasse 3 

|

 1210 Vienna, Austria  

 phone: +43 1 890 5033-0 

|

 e-mail: [email protected] 

|

 www.eralytics.com 

Содержание eravap

Страница 1: ...User Manual The full manual can be found on USB eravap Vapor Pressure Tester eralytics GmbH Lohnergasse 3 1210 Vienna Austria phone 43 1 890 5033 0 e mail office eralytics com www eralytics com...

Страница 2: ...months warranty period from date of installation 1 Warranty services will be rendered upon valid warranty registration with complete warranty information within 30 days from date of delivery The regi...

Страница 3: ...o _____________ Received test report _____________ Informed about cleaning when crude oil or other higher viscous samples are tested see section Cleaning _____________ Informed about handling of sampl...

Страница 4: ...5191 EN13016 1 D6377 and D5188 explained _____________ Measurement performed _____________ _________________ Location Date ______________________ ____________________ Customer operator name Sales repr...

Страница 5: ...sure testers EV01 EV02 EV10 EV20 The products to which this statement relates are manufactured and duly carried out in compliance with the provisions of European Community Directive 2014 35 EU 2014 30...

Страница 6: ...n of these documents eralytics GmbH assumes no responsibility for technical or printing errors or omissions Nor is any liability assumed for damages resulting from the use of the information contained...

Страница 7: ...Document Revision ERAVAP_a 8018 2 Telephone 43 1 890 50 33 0...

Страница 8: ...is not correctly installed Ensure that all operators are fully trained to use the analyzer correctly and safely Unqualified personnel must not operate the equipment Avoid causing damage to the equipm...

Страница 9: ...ce and maintenance Always disconnect the line cord of the apparatus when performing maintenance or moving the apparatus Do not use any accessories or wearing parts other than those supplied or approve...

Страница 10: ...Warranty shall apply to any Products which have been subjected to misuse neglect accident or without restricting the generality of the foregoing any extreme environmental condition or improper handlin...

Страница 11: ...licensed under GPL v2 and or GPL v3 The complete list of libraries and their license used can be viewed in the detailed software version information field and in the update menu under software licens...

Страница 12: ...ment of gasoline D5191 D6378 EN13016 1 EN13016 2 IP394 IP409 excellent correlation to ASTM D323 D4953 o EV01 D5188 Software module for the measurement of the vapor liquid ratio according to ASTM D5188...

Страница 13: ...lytics GmbH at 43 1 890 50 330 or office eralytics com immediately Retain and reuse the shipping boxes and packing materials as they provide optimal protection for the equipment s during transport e g...

Страница 14: ...e defined or measured V L ratio As for of the filling parameters the amount of liquid sample related to the total volume of the measuring cell is adjusted or pre defined by the used method Measuring t...

Страница 15: ...piston moves upwards to introduce the sample into the measuring cell The piston then is reset to the down position again to expel the liquid via the outlet valve After this rinsing procedure has been...

Страница 16: ...quired Optional extension EV01 COOL 20 C 120 C 4 F 248 F External cooling required Extrapolated range 100 C 300 C 148 F 572 F Temperature Stability 0 01 C 0 02 F Pressure Range EV10 ERAVAP 0 kPa 1000...

Страница 17: ...i instrument remote control convenient data transfer and result analysis Result Database Over 100 000 detailed test reports stored in internal memory Alarm Tracking All alarm messages are stored in th...

Страница 18: ...cal outlet It is recommended that the analyzer is plugged into its own circuit to avoid power line interference and voltage surges or drops which may occur if the circuit is shared with devices with h...

Страница 19: ...he inlet tube to the analyzer as described in the pictures below Waste container Mains Sample outlet RS232 interface Housing USB Type B plug slave Display Ethernet connector Filling tube with Luer con...

Страница 20: ...he Luer connector can be used For pressureized samples e g LPG crude oil with high amount of volatile substances the sampling tube with quickconnector right picture must be used Otherwise volatile sub...

Страница 21: ...k connector Quick connector inlet nut Example of pressurized sample container Press the main power switch The analyzer will load the firmware During this process the LED on the front is flashing The s...