www.prolight.co.uk
Stage Haze 1500
User Manual
6
Operating instructions
DMX mode:
Operating in a DMX control mode environment gives the user the greatest flexibility when it comes
to customising or creating a show. In this mode you will be able to control each individual trait of
the fixture and each fixture independently.
Press the
“FUNCTION”
button to display
‘The DMX device address set:’
, you can now adjust the DMX
address from 1 to 511 by using the and buttons.
You can then connect the DMX controller, the display will show
‘DMX-512 Add.:’
‘PMP: F:’
.
The PMP (haze output) and F (fan speed) can be adjusted via the DMX controller.
DMX channel mode:
Electronic Fluid-level-sensor:
If the fluid runs out whilst the unit is in operation the unit will continue to operate for approx. 2 minutes,
after this time the Electronic Fluid-level-sensor will stop the unit working to protect it. When this happens
the LCD display will flash and show
‘Beware: No Liquid!’
, this means the machine has run out of fluid,
please refill.
When this happens please do the following:
Power off the unit and disconnect from mains power supply.
Refill the fluid tank. (See page 4 for instructions on fluid replenishment)
Reconnect the mains power supply.
The unit can now be operated again.
Troubleshooting:
When the LCD display flashes and shows
‘Machine Temperature is too HIGH’
.
This could indicate the air filter on the side of the unit needs maintaining, please see page 7 for further
instructions. Alternatively this could indicate that the PCB is faulty. If the problem persists, please
contact your dealer.
When the LCD display flashes and shows
‘Temperature sensor error’
.
This could indicate that the heater is faulty and is not heating up or the heater isn’t getting up to the
right temperature. Please power the unit off and then back on. If the problem persists, please contact
your dealer.
Channel
Value
LCD display will show
Function
CH1
000-255
PMP (0-100%)
Haze output volume (0-100%)
CH2
000-255
F (0-100%)
Fan speed (slow-fast)