background image

Replacing the Plug Fuse (12/24V)

Pull off the adapter sleeve of the plug.
Unscrew the screw from the upper half of the housing.
Carefully raise the upper half of the housing from the lower half.
Take out the contact pin.
Replace the defective fuse with a new one that has the same rating.
Re-assemble the plug in the reverse order.

Replacing the PCB Light Blub

Shut off the power supply.
Carefully pry out the plastic light cover with a Flathead screwdriver.
Unscrew the PCB mounting screws.
Pull out the PCB.
Replace with a new PCB.
Fit the screws in with a screwdriver.
Press the transparent part of the lamp back into the housing.
Connect the power supply to the PFF.

Maintenance

Ensure the power cord is unplugged before moving or cleaning 
the appliance.

Clean the outside and inside of the appliance regularly, using a 
damp cloth and mild detergent.

Do not use abrasive materials to clean.

Remove all the food and beverage items.
Switch off the unit.
Pull out the power cable connection.
Leave the cover slightly open to prevent odors.

Do not wash under running water or immerse the PFF in water.

If turning Off the PFF for long periods of time:

·

·

·

·

·

·

·

·
·
·

·

·

·

·

·

·
·

·

7

Содержание PFF 07

Страница 1: ...Read the instructions carefully and keep for future reference OWNER S MANUAL Model PFF 07 PORTABLE FRIDGE FREEZER...

Страница 2: ...oes not cover service calls which do not involve defective workmanship or materials covered by this warranty Accordingly diagnosis and repair costs for a service call which does not involve defective...

Страница 3: ...or Customer Service This warranty is given by Equator Appliances 10216 Georgibelle Drive Suite 900D Houston Texas 77043 5249 Since it is a responsibility of the consumer owner to establish the warrant...

Страница 4: ...t Do not use a damaged power cord Do not use an extension cord Do not use mechanical devices or sharp tools to accelerate the defrosting process Never immerse the appliance in water Never handle plugs...

Страница 5: ...away from walls and other obstructions A maintenance free refrigerant circuit with a compressor provides the cooling function Place the appliance out of direct sunlight and away from sources of heat...

Страница 6: ...connection cable to AC mains supply When connected to the DC socket disconnect it or turn Power o when the engine is turned o to prevent discharge of the battery There is an Emergency Override switch...

Страница 7: ...safety reasons the PFF is equipped with an electronic system to prevent polarity reversal This protects it against short circuiting when connected to a battery Plug the 12 24V connection cable into t...

Страница 8: ...or Press the Set button one time to input the desired temperature Setting Temperature The and buttons enable selection of the temperature by increasing or decreasing in one degree increments The Displ...

Страница 9: ...Mode Switch o voltage at 12 V Restart voltage at 12 V Switch o voltage at 24 V Restart voltage at 24 V H1 H2 H3 10 1 V 11 1 V 21 5 V 23 0 V 11 4 V 12 2 V 22 5 V 24 0 V 11 8 V 12 6 V 23 0 V 24 5 V Pre...

Страница 10: ...B mounting screws Pull out the PCB Replace with a new PCB Fit the screws in with a screwdriver Press the transparent part of the lamp back into the housing Connect the power supply to the PFF Maintena...

Страница 11: ...ating from 12 24V socket cigarette lighter it may have debris resulting in poor electrical contact Clean debris from socket In addition to the Troubleshooting table above the following Error Codes may...

Страница 12: ...ss Product Dimensions HxWxD Packaging Dimensions HxWxD PFF 07 0 7 cu ft DC 12V 24V 4 2 A 2 1a 50 W R134a 0 F 50 F 27 5 30 8 lbs 12 6 x 22 4 x 12 7 inch 15 6 x 25 4 x 15 7 inch O O WARNING This product...