background image

 

 

 

11

Installing the

 

Beer Keg 

·

 

Position the beer keg directly  in front  of the open  door. Using keg handles only,  carefully  lift the 
beer keg. (See Figure 5) 

·

 

To place the beer keg inside the cabinet, brace your knees behind the beer keg. Lift the front of 
the keg just enough so the front edge of the keg is resting on the front edge of the Beer Cooler 
bottom cabinet. (See Figure 6) 

·

 

Grasp the keg handles and slide it all the way into the cabinet.  

 
 
 
 
 
 
 
 
 

Fig. 4

                                    

Fig. 5

                           

Fig. 6

 

 

Installing the

 

Keg Coupler 

·

 

Insert the keg coupler provided into the locking neck of the beer keg and turn it clockwise to lock 
into position, making sure the keg coupler is in the closed position. (See Figure 7) 

 

Installing the

 

CO

2

 Air Line Hose 

·

 

Attach the end of the air line (red) hose provided to the hose connection on the keg coupler. 

Secure hose by using the clamps and make sure there are no leaks. 

 

Connecting the beer tower to coupler 

·

 

Make sure the washer is properly inserted into the wing nut. 

·

 

Place wing nut into the top of the coupler turning until tight. 

 

How to Tap a Keg of Beer 

·

 

Make sure the beer tower faucet is in the closed position. 

·

 

Pull tapping handle out and press downward until it locks into position. (See Figure 8) The keg is 
now tapped. 

 

Opening the CO

2

 Cylinder Main Valve 

·

 

Before  doing  that,  make  sure  the  secondary  shut-off  valve  is  closed,  as  shown  in  figure  9.  To 
open the main CO

2

 cylinder valve, slowly turn the main valve counter-clockwise until fully open. 

·

 

Notice the needle on the gauge start to climb. 

 

Adjusting the CO

2

 Regulator 

·

 

The gauge monitors low internal keg pressure and should be adjusted to read between 10-12 psi. 
(See Figure 10) 

·

 

In order to do that: 

1. 

Release adjustment lock nut marked 2.

 

2.  Using a flat screwdriver, turn regulator screw marked 3. If increased low

 

pressure is sought, 

rotate screw clockwise. By rotating it counter clockwise, low pressure will be decreased when 
the required operating pressure is attained, retighten lock nut 2.  

3.  Open secondary shut off valve to let CO

2

 flow into the keg. 

Содержание BCR 500

Страница 1: ...BEER COOLER Model No BCR 500 OWNER S MANUAL To ensure proper use of this appliance and your safety please read the following instructions completely before operating this appliance...

Страница 2: ...___________________________________ 8 Installation Instructions for Beer Keg ______________________________ 9 12 Dispensing of Beer ________________________________________________ 13 Operating Your B...

Страница 3: ...s be liable for incidental or consequential damages or for damages resulting from external causes such as abuse misuse incorrect voltage or acts God This warranty does not cover service calls which do...

Страница 4: ...er owner to establish the warranty period by verifying the original purchase date the Equator Advanced Appliances recommends that a receipt delivery slip or some other appropriate payment record be ke...

Страница 5: ...2 Plastic Gasket 3 Safety Guard Rail 4 Drip Tray 5 Adjustable Thermostat 6 CO2 Regulator 7 CO2 Gas Cylinder 8 CO2 Gas Cylinder Support 9 Evaporator 10 Reversible Door 11 Beer Keg not included 12 Meta...

Страница 6: ...Take off the doors Leave the shelves in place so that children may not easily climb inside Never allow children to operate play with or crawl inside the unit Refrigerants All refrigeration products c...

Страница 7: ...r built in Place your Beer Cooler on a floor that is strong enough to support the Beer Cooler when it is fully loaded Allow 3 inches of space between the back and sides of the Beer Cooler which allows...

Страница 8: ...CO2 cylinders BEFORE INSTALLATION 1 ALWAYS connect the CO2 cylinder to a regulator Failure to do so could result in explosion with possible injury when the cylinder valve is opened 2 NEVER connect the...

Страница 9: ...ation Diagram Installing the Casters Install the four casters with lock provided into the unit s bottom four screw holes pre supplied The two metal gaskets are used for the front two Casters I Before...

Страница 10: ...he uncovered hole See Figure 4 Installing the CO2 Air Line Hose To Regulator Attach the open end of the red hose to the hose barb connection on the regulator Secure hose by using one clamp provided Us...

Страница 11: ...ake sure the washer is properly inserted into the wing nut Place wing nut into the top of the coupler turning until tight How to Tap a Keg of Beer Make sure the beer tower faucet is in the closed posi...

Страница 12: ...handle provided on the top of the faucet tightening it by hand clockwise until the end holding in the silver snug underneath so it does not move If there is still a small drip from the faucet you may...

Страница 13: ...just the temperature control to the desired setting The range of temperature control is from position 1 the warmest to 6 the coldest Temperature range of the thermostat goes from 36 F to 45 F 2 2 C to...

Страница 14: ...g coupler 5 Drain any remaining beer from the lines 6 Disconnect the beer line and CO2 air line from the keg coupler 7 Remove the beer keg 8 Remove the keg coupler 9 Disconnect the air line from the C...

Страница 15: ...left or right side The unit is delivered to you with the door opening from the left side Should you desire to reverse the opening direction please follow below instructions Caution To avoid personal...

Страница 16: ...d liquid detergent Rinse well and wipe dry with a clean soft cloth Vacation Time Short vacations Leave the Beer Cooler operating during vacations of less than three weeks Long vacations If the applian...

Страница 17: ...is not set correctly The door gasket does not seal properly The Beer Cooler does not have the correct clearances Vibrations Check to assure that the Beer Cooler is level The Beer Cooler seems to make...

Страница 18: ...Georgibelle Suite 900D Houston TX 77043 2459 Tel 713 464 3422 Fax 713 464 2151 www EquatorAppliances com SERVICE SUPPORT custserv ApplianceDesk com 800 776 3538 www ApplianceDesk com Allrightsreserve...