Installing the CO

Cylinder Support

 

·

 

Install the metal support provided onto the 4 studs located on the exterior back wall. Align the 
holes in the support with the studs and push down firmly. (See Figure 1) 

 
 

Installing the CO

2

 Cylinder 

·

 

Install your fully charged cylinder into the support stand. 

 
 

Installing the CO

2

 Regulator 

·

 

Attach the CO

2

 regulator to the cylinder by turning the regulator nut onto cylinder valve, making 

sure washer is securely inserted into connecting nut. Tighten snug using an adjustable wrench 
(not supplied) and assure there are no leaks. (See Figure 2) 

 
 

Installing the

 

CO

Air Line Outside Cabinet 

·

 

Remove plug located at the exterior back (top left hand corner). 

·

 

Save it for later use if you decide to convert unit to an all refrigerator.  

·

 

Insert the open end of the air line (red) line the cabinet through the uncovered hole. 
(See Figure 4) 
 
 

Installing the

 

CO

2

 Air Line Hose To Regulator  

·

 

Attach the open end of the red hose to the hose barb connection on the regulator 

·

 

Secure hose by using one clamp provided. Use pliers/screwdriver to tighten clamp to prevent 
leaks. (See Figure 3) 

 
 
Installing the Beer Tower 

·

 

Remove the top plug by twisting and pulling out, saving it for later use if you decide to convert unit 
to an all refrigerator unit. 

·

 

Unravel the beer line (clear hose) from the tower and insert the beer line and wing nut through the 
uncovered hole on top.  

·

 

Lock the beer tower assembly to the top and make sure to position the beer faucet so it is aligned 
with the cabinet front (6 o’clock position). You accomplish this by aligning the bottom of the beer 
tower to the 3 grooves on the top cabinet and tighten by hand clockwise to properly lock. 

 
 

 

Installing the

 

Protective Metal Plate  

·

 

This  plate  should  always  be  installed  when  the  keg  is  in  place  to  protect  against  unnecessary 
damage to the floor of the cabinet.  

 
 

Fig. 1 

Fig. 2 

Fig. 3 

Содержание BCR 500

Страница 1: ...BEER COOLER Model No BCR 500 OWNER S MANUAL To ensure proper use of this appliance and your safety please read the following instructions completely before operating this appliance...

Страница 2: ...___________________________________ 8 Installation Instructions for Beer Keg ______________________________ 9 12 Dispensing of Beer ________________________________________________ 13 Operating Your B...

Страница 3: ...s be liable for incidental or consequential damages or for damages resulting from external causes such as abuse misuse incorrect voltage or acts God This warranty does not cover service calls which do...

Страница 4: ...er owner to establish the warranty period by verifying the original purchase date the Equator Advanced Appliances recommends that a receipt delivery slip or some other appropriate payment record be ke...

Страница 5: ...2 Plastic Gasket 3 Safety Guard Rail 4 Drip Tray 5 Adjustable Thermostat 6 CO2 Regulator 7 CO2 Gas Cylinder 8 CO2 Gas Cylinder Support 9 Evaporator 10 Reversible Door 11 Beer Keg not included 12 Meta...

Страница 6: ...Take off the doors Leave the shelves in place so that children may not easily climb inside Never allow children to operate play with or crawl inside the unit Refrigerants All refrigeration products c...

Страница 7: ...r built in Place your Beer Cooler on a floor that is strong enough to support the Beer Cooler when it is fully loaded Allow 3 inches of space between the back and sides of the Beer Cooler which allows...

Страница 8: ...CO2 cylinders BEFORE INSTALLATION 1 ALWAYS connect the CO2 cylinder to a regulator Failure to do so could result in explosion with possible injury when the cylinder valve is opened 2 NEVER connect the...

Страница 9: ...ation Diagram Installing the Casters Install the four casters with lock provided into the unit s bottom four screw holes pre supplied The two metal gaskets are used for the front two Casters I Before...

Страница 10: ...he uncovered hole See Figure 4 Installing the CO2 Air Line Hose To Regulator Attach the open end of the red hose to the hose barb connection on the regulator Secure hose by using one clamp provided Us...

Страница 11: ...ake sure the washer is properly inserted into the wing nut Place wing nut into the top of the coupler turning until tight How to Tap a Keg of Beer Make sure the beer tower faucet is in the closed posi...

Страница 12: ...handle provided on the top of the faucet tightening it by hand clockwise until the end holding in the silver snug underneath so it does not move If there is still a small drip from the faucet you may...

Страница 13: ...just the temperature control to the desired setting The range of temperature control is from position 1 the warmest to 6 the coldest Temperature range of the thermostat goes from 36 F to 45 F 2 2 C to...

Страница 14: ...g coupler 5 Drain any remaining beer from the lines 6 Disconnect the beer line and CO2 air line from the keg coupler 7 Remove the beer keg 8 Remove the keg coupler 9 Disconnect the air line from the C...

Страница 15: ...left or right side The unit is delivered to you with the door opening from the left side Should you desire to reverse the opening direction please follow below instructions Caution To avoid personal...

Страница 16: ...d liquid detergent Rinse well and wipe dry with a clean soft cloth Vacation Time Short vacations Leave the Beer Cooler operating during vacations of less than three weeks Long vacations If the applian...

Страница 17: ...is not set correctly The door gasket does not seal properly The Beer Cooler does not have the correct clearances Vibrations Check to assure that the Beer Cooler is level The Beer Cooler seems to make...

Страница 18: ...Georgibelle Suite 900D Houston TX 77043 2459 Tel 713 464 3422 Fax 713 464 2151 www EquatorAppliances com SERVICE SUPPORT custserv ApplianceDesk com 800 776 3538 www ApplianceDesk com Allrightsreserve...

Отзывы: