6. LIGHTING AND REGULATING COMBUSTION
Follow the instructions below to regulate combustion:
LIGHTING THE UNIT:
Open the air wash valve (fig2)
It is advisable
to leave the door partially open to avoid condensation and keep the glass
clean for some minutes after lighting the fire.
COMBUSTION CONTROL
:
Once the fireplace has got going at its normal level and the chimney has heated up,
regulate combustion by means of the regulation lever. When the inflow of air is fully closed,
combustion will be slow; when the inflow of air is open, combustion will be more intense.
ATTENTION! When working, the metal parts of the fireplace may reach high
temperatures. Protect your hands with a fireproof glove when touching the said
parts.
If you should detect any overheating of the fireplace caused by:
Fan breakdown.
Faulty thermostat.
You should shut down the device in order to avoid damaging cast iron parts. Follow these
recommendations:
Do not add any more fuel
Open the door slightly to le
t more air in; this will cause the flames to grow and consume the fuel more quickly but
will also cool the chimney and reduce draw, cooling the device
Your Insert Fireplace has been designed to operate with an intermittent combustion
system.
Fig. 2
Catalyzer closed when
starting
the
unit
(ignition)
Catalyzer
opened
when
burning
at
normal conditions.