72
73
Configuration menu
Configuration menu
• Confirm your setting using the boost button ( ).
• Set the option „On“ to activate automatic switching or set
the option „OFF“ to deactivate automatic switching with
the handwheel.
• Confirm with the boost button ( ).
15.5 Setting offset temperature (tOF)
As the temperature is measured on the room thermostat,
the temperature distribution can vary throughout a room.
To adjust this, a temperature offset of ±3.5 °C can be set.
If a nominal temperature of e.g. 20 °C is set but the room
presents with only 18 °C,an offset of -2.0 °C needs to be
set. The offset temperature can be adjusted individually.
An offset temperature of 0.0° is set in the factory settings.
• Press the auto/manu button ( ) longer than 3 seconds.
• Select the menu item „tOF“ with the handwheel and con-
firm with the boost button ( ).
• Turn the handwheel and set the desired offset tempera-
ture (max. ±3.5 °C).
• Confirm the setting with the boost button ( ).
15.6 Display of setpoint and actual tempera-
ture (S-A(
In the configuration menu under “S-A” the permanent dis-
play of the setpoint or actual temperature can be adjusted.
• Press the auto/manu button ( ) longer than 3 seconds.
• Select the menu item „S-A“ with the handwheel and con-
firm with the boost button ( ).
• Select “ACt” to display the actual temperature and “SEt”
to display the setpoint temperature.
• Confirm with the boost button ( ).
15.7 Change between actual temperature and
humidity (t-H)
In the configuration menu under “t-H” the automatic switch
between the actual temperature and humidity can be acti-
vated or deactivated. If the automatic switch is deactivated
(“OFF”), only the actual temperature will be displayed.
• Press the auto/manu button ( ) longer than 3 seconds.
• Select the menu item „t-H“ with the handwheel and con-
firm with the boost button ( ).
• Set the option „On“ to activate automatic switching or set
the option „OFF“ to deactivate automatic switching with
the handwheel.
• Confirm with the boost button ( ).
Switch between the actual temperature and
humidity is only possible if the actual temperature
has been selected under “S-A”.
15.8 Teach-out devices (dEL)
Devices that are taught-in to the room thermostat can be
taught-out with the function “dEL”. All taught-in devices are
deleted simultaneously.
• Press the auto/manu button ( ) longer than 3 seconds.