23
The energy-saving controller can only be installed if “INS”
is showing on the display. Following installation, the actua-
tor will perform an adjustment run so that it can adapt to the
valve. During this process, “ADA” will be displayed.
Place the actuator on the valve.
•
Tighten the union nut.
•
“INS” will appear on the display, press the OK button.
•
The actuator will perform an adjustment run (“ADA” will
•
appear on the display, operation not possible).
After that, the actuator will be ready for operation (Auto
•
mode).
If the adjustment run was initiated prior to installa-
tion, or if an error message will be displayed (F1, F2,
F3); press OK to move the motor back to the “INS”
position.
1. Setting the weekly program
The weekly program allows you to set up to 3 separate
heating periods (7 switching times) for each day of the
week. Programming is performed in relation to the se-
lected days, for which temperatures must be stored for a
period from 00:00 to 23:59.
Press and hold down the menu button for more than 3 seconds.
“PRO” will appear on the display.
•
Confirm with OK.
•
“DAY” will appear on the display. The setting wheel can
•
be used to select an individual day of the week, all wor-
king days, the weekend or the entire week (example
shows working days selected).
Confirm with OK.
•
The first setting time will appear on
•
the display (0:00). This cannot be
changed. In addition, the display
shows bars for every other swit-
Содержание C Classic
Страница 66: ...66...
Страница 67: ...67...
Страница 68: ...68 eQ 3 AG Maiburger Stra e 29 D 26789 Leer www eQ 3 com...