Confidential
Fatal Error Code List
28
EPSON WF-R8590/WF-R8591/WF-R8593
Revision F
ADF/Scanner fatal error list
Table 1-4. Fatal Error List (ADF/Scanner)
Error
type
Error
code
Error
name
0x01
ADF PID excess speed error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• Motor driver failure (SCN Main board failure)
0x02
ADF PID reverse error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• Paper jam
0x03
ADF PID (Proportional Integral Derivative
Controller) lock error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF motor failure
• Paper jam
• Cable disconnection
0x 04
ADF PID acce leration lock d etection er ror
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF motor failure
• Paper jam
• Cable disconnection
0x05
ADF PID excess load error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF motor failure
• Paper jam
• Cable disconnection
0x06
ADF PID driving time error
• SCN Main board failure
0x09
ADF BS+ excess speed error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• Motor driver failure (SCN Main board failure)
0x0A
ADF BS+ reverse error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• Paper jam
0x0B
ADF BS+ lock error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF Motor failure
• ADF drive overload (paper jam, foreign object)
• Cable disconnection
0x0D
ADF BS+ excess load error
• ADF Encoder failure (contaminated/detached scale, Encoder Board
failure)
• ADF motor failure
• ADF drive overload (paper jam, foreign object)
• Cable disconnection
0x0E
ADF BS+ driving time error
• SCN Main board failure
0x10
HP detection error
• CIS Unit failure
• Scanner Housing failure
• SCN Main board failure
0x 11
Con tac t d etection d is tance exceeded error
• CIS Unit failure
• Scanner Housing failure (Including wrong attachment of the origin mark)
• SCN Main Board failure
• Scanner FFC failure / Scanner FFC connection failure
• Scanner Motor failure / Scanner Motor connection failure
0x12
Opposite side contact detection distance
exceeded error
• CIS Unit failure
• Scanner housing failure (Including wrong attachment of the origin mark)
• SCN Main board failure
• Scanner FFC failure / Scanner FFC connection failure
• Scanner motor failure / Scanner motor connection failure