TM-T60/T60 DIP-Switch Functions
Table 3-2 DIP-Switch Functions (On the bottom of the case)
DIP SW1
ON
OFF
SW- 1
Ignores data reception errors
Prints “?” for data reception
- - - - - - - - - - - - - - - - - -
SW-2 Data buffer
- - - - - - - - - - - - - -
SW3 XON/XOFF
- - - - - - - - - - - -
SW-4 Parity
----------------------
SW-5 Even parity
- - - - - - - - - - - - - - - - - - - -
S W - 6
S W - 7
S W - 8
S W - 9
errors
---------------------.-----------------------------------
45 bytes
Data buffer 4 Kbytes
---------------------------------------------------------
control
DTR/DSR control
---------------------------------------------------------
No Parity
---------------------------------------------------------
Odd parity
---------------------------------------------------------
Change baud rate (Refer to Table 3-3)
Change print density (Refer to Table 3-4)
w - 1 0
Normally OFF
Table 3-3. Baud Rate Selection
Baud Rate SWl - 6 SW1 - 7
1200 bps
O N
O N
4800
OFF
O N
9600
O N
O F F
19200
O F F
O F F
Table 3-4. Print Density Selection
Print Density
SW1
-8
SW1 -9 Level
LIGHT
ON
ON
1
OFF OFF 2
---------------------------------------
ON OFF 3
---------------------------------------
DARK
OFF
ON
4