EPSON Stylus COLOR C70/C80
Revision A
Troubleshooting
Overview
63
3.1.3 Status Monitor does not operate
This section describes the procedures for checking printers when the Status Monitor
suddenly can no longer be used to check the printer status, even though the Status
Monitor has been operating normally before.
Table 3-3. Communication Error Checking Point
Step
Check Point
Remedy
1
Use the
adjustment
program to
check the
64H address
(IEEE 1284.4
for parallel)
for the
EEPROM.
The relationship between the IEEE 1284.4 for Parallel setting status
and the setting values is given below.
00H: Auto (Status cannot be sent to the computer when the printer has
an error)
01H: On (Default: Status can be sent to the computer even if the
printer has an error)
02H: Off (Status cannot be sent to the computer regardless of the
printer status)
To reset, use the Dump function of the adjustment software to rewrite
the setting to the default (01H). Refer to Chapter 5 for details.
NOTE:
The Stylus COLOR C80 has a default setting function, but
there is no function available for the customer to change the
setting for the 64H address. Furthermore, the Stylus COLOR
C70 does not have its own default setting function. Even if the
default value (01H) is changed to 00H or 02H, the EEPROM
data may become corrupted, so even if the communication
problem is fixed, there is a high possibility that the various
adjustment values may be distorted. Because of this, all
parameter electrical adjustments should be carried out afresh.
Refer to Chapter 5 for details.
2
Use the
adjustment
program to
check the
65H address
(IEEE 1284.4
for USB) for
the
EEPROM.
The relationship between the IEEE 1284.4 for Parallel setting status
and the setting values is given below.
00H: Auto (Status cannot be sent to the computer when the printer
has an error)
01H: On (Default: Status can be sent to the computer even if the
printer has an error)
02H: Off (Status cannot be sent to the computer regardless of the
printer status)
To reset, use the Dump function of the adjustment software to rewrite
the setting to the default (01H). Refer to Chapter 5 for details.
NOTE:
The Stylus COLOR C80 has a default setting function, but
there is no function available for the customer to change the
setting for the 65H address. Furthermore, the Stylus COLOR
C70 does not have its own default setting function. Even if the
default value (01H) is changed to 00H or 02H, the EEPROM
data may become corrupted, so even if the communication
problem is fixed, there is a high possibility that the various
adjustment values may be distorted. Because of this, all
parameter electrical adjustments should be carried out afresh.
Refer to Chapter 5 for details.
3
Has the
printer driver
been installed
correctly?
If the problem cannot be reproduced at the Service Center, get the
customer to reinstall the driver and re-check.
Table 3-3. Communication Error Checking Point
Step
Check Point
Remedy
Содержание Stylus Color C70
Страница 1: ...EPSONStylusColorC70 C80 Color Inkjet Printer SEIJ01 004 SERVICE MANUAL ...
Страница 5: ...Revision Status Revision Issued Date Description A July 31 2001 First Release ...
Страница 9: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 35: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 60: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 96: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 137: ...C H A P T E R 5 ADJUSTMENT ...
Страница 169: ...C H A P T E R 6 MAINTENANCE ...
Страница 182: ...C H A P T E R 7 APPENDIX ...
Страница 214: ......
Страница 215: ......
Страница 216: ......