73
4.2.8 CR motor removal
1.
Remove the upper housing. (Refer to Section 4.2.1)
2.
Move the carriage to the center.
3.
Press on the driven pulley and loosen the timing belt, then remove the timing belt
from the CR pinion gear.
Figure 4-30. Removing the Timing belt
4.
Take out the screw, then remove the CR motor from the frame.
Figure 4-31. Removing the CR motor
5.
Disconnect connector CN7 from the MAIN board then disconnect the cable.
Driven pulley
Timing belt
CR pinion gear
CR motor
CBS 3
×
6
When reassembling the CR motor, it contact the lib of Main
frame after turning clockwise.
Figure 4-32. Reassembling the CR motor
Tightening Torque for screw
- C.B.S 3x6 screw
: 9+/-1 kgf.cm
A D J U S T M E N T
R E Q U I R E D
The Bi-D adjustment is required when the CR motor is removed
or replaced. Refer to Table 5-1
lib
Содержание Stylus C40UX
Страница 1: ...StylusC40UX C40SX C20UX C20SX Color Inkjet Printer SEIJ01002 SERVICE MANUAL ...
Страница 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 24: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 44: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 56: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 78: ...C H A P T E R 5 ADJUSTMENT ...
Страница 97: ...Stylus C40UX C40SX C20UX C20SX Revision B Adjustment Overview 97 Figure 5 32 A4 Check pattern ...
Страница 98: ...C H A P T E R 6 MAINTENANCE ...
Страница 103: ...C H A P T E R 1 9 7 APPENDIX ...
Страница 120: ......
Страница 121: ......
Страница 122: ......
Страница 123: ......
Страница 124: ......
Страница 125: ......