background image

 

______________________________________________________________________________________________________ 
PIS # S050192                                                                                                                                                      Version 3.8 (USA) 
Page 2 of 4                                                                                                                                                    Release Date 09/01/12 

 

Inhalation:

  Intentional exposure to toner may cause respiratory irritation.  See Section 11 for Toxicology. 

 

Ingestion:

  May cause upset stomach.  See Section 11 for Toxicology. 

 

 

4.    

First Aid Measures 

 

4.1 

Eyes

:  Immediately flush with room temperature, low pressure, clean water for at least 15 minutes.  Seek medical 

attention if eye irritation continues. 

 

4.2 

Skin

:  Wash surface areas with soap and water.  Wash soiled clothing before re-wearing.  Seek medical attention if 

irritation continues. 

 

4.3 

Inhalation

:  Remove subject to ventilated fresh air and rinse mouth.  Consult physician if necessary or if cough 

develops. 

 

4.4 

Ingestion

:  Rinse mouth with water.  Seek medical attention if stomach continues to be upset.  

 
 

5.         Fire Fighting Measures 

 

 

Flammability

:  Flash point is greater than 230 deg. F / 110 deg. C (closed cup in accordance with ASTM D3278) 

 
 

Extinguishing Media

:  Dry chemical or carbon dioxide 

 
 

Fire Fighting Instructions

:  Breathing apparatus required.  No special explosive hazards are known. 

 
 

6.    

Accidental Release Measures 

 

Shut off ignition sources.  If a spill occurs, use sponges to wipe-up toner, then rinse area with damp cloth.  Place 
waste in closed container for disposal.  Use proper ventilation.  Do not dispose of waste to the sewer.  No eye or skin 
protection required during clean-up.  Wash hands with soap and water. 

 
 

7.    

Precautions for Safe Handling and Use 

 

Keep out of reach of children and do not dismantle or incinerate cartridge.  Keep cartridge in dark, cool, dry, and well 
ventilated are.  Do not store cartridges with oxidizing agents.  Make sure cartridge is dry before insertion into printer 
housing.  Avoid dispersing toner.    

 
 

8.    

Exposure Controls and Personal Protection 

 
 

Engineering Controls

:  None required when cartridges are used as intended 

 
 

Exposure Controls

:  None required when cartridges are used as intended.  Otherwise, 

                                        ACGIH TLV (2003):  10mg/cubic meter (total) 
                                                                           3mg/cubic meter (respiratory)   
 

 

 
 

Personal Protection

:  None required when cartridges are used as intended 

 
 

9.          Physical and Chemical Properties of Toner Formulation 

 
 

Appearance

 

Moist Magenta Powder 

 

Odor

 

Slight 

 

pH

 

Organically neutral

 

 

Boiling point

 

Not applicable 

 

Freezing point

 

Not applicable 

Содержание S050192

Страница 1: ...S No By Weight Styrene Acrylate polymer mixture 60 70 Mn Mg Sr ferrite powder 10 20 Proprietary acrylic resin 1 10 Proprietary red pigment 1 10 Amorphous silica 7631 86 9 1 10 Carbon black 1333 86 4 1 10 Titanium dioxide 13463 67 7 1 3 Hazard Identification 3 1 Emergency Overview Toner is a moist magenta powder that may cause eye irritation Avoid contact with eyes or clothing In the case of skin c...

Страница 2: ...re Fighting Instructions Breathing apparatus required No special explosive hazards are known 6 Accidental Release Measures Shut off ignition sources If a spill occurs use sponges to wipe up toner then rinse area with damp cloth Place waste in closed container for disposal Use proper ventilation Do not dispose of waste to the sewer No eye or skin protection required during clean up Wash hands with ...

Страница 3: ...ical developer a mild to moderate degree of lung fibrosis was observed in approximately 90 of rats in the high concentration exposure group 16mg cubic meter and a minimal to mid degree of fibrosis was noted in approximately 20 of the animal in the middle exposure group 4mg cubic meter But no pulmonary change was reported in the lowest exposure group 1mg cubic meter the most relevant level to poten...

Страница 4: ...Flammability 1 Instability Reactivity 0 Other 0 EU RoHS compliant Yes California Proposition 65 Yes titanium dioxide CAS 13463 67 7 as 1 0 by weight of toner formulation 16 Other Information This PIS adheres to U S regulatory requirements and standards and may not meet the regulatory requirements in other locations This is a revised Product Information Sheet which replaces all prior U S PIS for th...