RX8130
CE
Page
2
ETM50E-05
3. Terminal description
3.1. Terminal connections
RX8130CE
1. V
IO
10. V
BAT
2. SCL
9. V
OUT
3. SDA
8. V
DD
4. FOUT
7. GND
5. /RST
6. /IRQ
3.2. Pin Functions
Signal
name
I/O
Function
SCL
Input
Serial clock input pin.
SDA
Bi-directional
Data input and output pin.
FOUT
Output
Frequency output pin with output control function. (CMOS)
Output frequency can be selected as 32.768kHz, 1024Hz, 1Hz.
/ RST
Open-Drain
Output
Even in the backup mode, this pin can opperate. In case of V
DD
voltage drop detection, a
reset signal is outputted.
In case of V
DD
voltage rise detection, it releases the reset signal after 60ms.
/ IRQ
Open-Drain
Output
Interrupt output by Alarm and Timer events.(N-ch open drain)
This pin can output even a backup mode.
V
DD
This is a power-supply pin for the internal logic.
V
IO
This is a interface power supply pin. (There is an level shifter between VDD and VIO)
V
OUT
Internal voltage output pin.
Connect smoothing capacitor of 1.0uF
V
BAT
This is a power supply pin for backup battery.
This is a pin to connect a large-capacity capacitor, a secondary battery, and a primary
battery.
In a backup mode, the voltage is supplied inside by this pin.
GND
Connected to a ground.
Note: Connect a bypass capacitor rated at least 0.1μF between power supply pins and GND pin.
Note:
Input pins are able to input up to 5.5V regardless of V
IO
applied voltage.
Note: Open drain pins are able to Pull-up to 5.5V regardless of V
IO
applied voltage.
Note: Use the FOUT, /RST, /IRQ terminals as OPEN when not in use.
4.
Examples of external connection
4.1. Examples of power supply connection
V
DD
V
BAT
V
IO
VD1.8
VD3
R
0.1
F
secondary
battery
EDLC
or
0.1
F
1.0
F
V
OUT
0.1
F
V
DD
V
BAT
V
IO
VD3
VD3
R
0.1
F
secondary
battery
EDLC
or
1.0
F
V
OUT
0.1
F
V
DD
V
BAT
V
IO
VD3
R
0.1
F
Primary
battery
1.0
F
V
OUT
0.1
F
(2) Same I/F voltage and
charge voltage
(CHGEN=1, INIEN=1)
(3) Primary battery as backup
(CHGEN=0)
(1) Case of different I/F voltage
and charge vlotage