RX8111CE
Page
−
50
ETM61E-01
14.9. Flow Chart
Below are examples of flow charts, but they are not necessarily applicable for every use-case and not necessarily the most
effective process for individual applications. For effective processing, user can do multiple execution, change ordering, eliminate
execution etc.
These flow should be optimization for suitable in each of system.
1) Power on initializing example
•
After internal oscillation start VLF can be cleared to
“0”.
Start
Wait
•
At least 40 ms wait time is needed.
So that it is stable RTC.
40 ms is not oscillation startup time.
•
When RTC returned from battery backup normally, VLF is 0.
and after initial power On, VLF is 1.
•
When VLF is 1, recommended initializing all register data.
VLF=1 ?
YES
YES
NO
VLF=
”0” clear
Wait
VLF=0 ?
NO
•
Waiting suitable time, in each of system.
more than 300 ms is recommended
Power on
Start-up complete
Initialize
Figure 38 Example flow (power on initialization)