RX8111CE
Page
−
18
ETM61E-01
13.2.2. Register Initial Value After Power on Reset
This table describes initial values after power on reset.
Note: Registers marked “X” should be initialized to 0, except time stamp area.
Table 11 Register Initial value (1)
Address
Function
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
10h
SEC
X
X
X
X
X
X
X
X
11h
MIN
0
X
X
X
X
X
X
X
12h
HOUR
0
0
X
X
X
X
X
X
13h
WEEK
0
X
X
X
X
X
X
X
14h
DAY
0
0
X
X
X
X
X
X
15h
MONTH
0
0
0
X
X
X
X
X
16h
YEAR
X
X
X
X
X
X
X
X
17h
MIN Alarm
1
X
X
X
X
X
X
X
18h
HOUR Alarm
1
X
X
X
X
X
X
X
19h
WEEK Alarm
1
X
X
X
X
X
X
X
DAY Alarm
X
X
X
X
X
X
X
1Ah
Timer Counter 0
X
X
X
X
X
X
X
X
1Bh
Timer Counter 1
X
X
X
X
X
X
X
X
1Ch
Timer Counter 2
X
X
X
X
X
X
X
X
1Dh
Extension Register
0
0
0
0
0
0
1
0
1Eh
Flag Register
1
0
0
0
0
0
1
X
1Fh
Control Register
0
0
0
0
0
0
0
0
Address
Function
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
20h
Time Stamp 1/1024S
0
0
0
0
X
X
X
X
21h
Time Stamp 1/256S
X
X
X
X
X
X
X
X
22h
Time Stamp SEC
0
X
X
X
X
X
X
X
23h
Time Stamp MIN
0
X
X
X
X
X
X
X
24h
Time Stamp HOUR
0
0
X
X
X
X
X
X
25h
Time Stamp WEEK
0
X
X
X
X
X
X
X
26h
Time Stamp DAY
0
0
X
X
X
X
X
X
27h
Time Stamp MONTH
0
0
0
X
X
X
X
X
28h
Time Stamp YEAR
X
X
X
X
X
X
X
X
29h
Status Stamp
0
0
X
X
X
0
X
0
2Ah
No Function
0
0
0
0
0
0
0
0
2Bh
EVIN Setting
0
0
0
0
0
0
0
0
2Ch
SEC Alarm
0
0
0
0
0
0
0
0
2Dh
Timer Control
0
0
0
0
0
0
0
0
2Eh
Time Stamp control 0
0
0
0
0
0
0
0
0
2Fh
Command Trigger
0
0
0
0
0
0
0
0
X : Undefined. 0 or 1
0 : Reset state
1 : Set state