58
EMP-S1 User’s Guide
Appendices > Projector Care
f
Resetting the lamp operating time
The projector has a built-in counter which keeps track of the lamp
operating time and causes the replacement warning message to be
displayed when the cumulative operating time reaches a certain point.
Therefore, the counter needs to be reset from the configuration menu, after
the lamp has been replaced with a new one.
A
Turn on the power and press the [Menu] button.
B
Select "Lamp Hours Reset" from the "Reset" menu,
using the [
u
][
d
][
e
] buttons.
C
Use the [
l
][
r
] buttons to select "Yes", then press the
[
e
] button.
The lamp operating time will be reset.
p
Please do not reset the lamp operating time except when the
lamp has been changed. Otherwise, the lamp operating time will
not be displayed correctly.