3-20
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON
Revision:A
3.3.8 Lens Shutter’s Operation Check
Flowchart 3-10 Lens Shutter’s Check
Start
2. Replace Shutter Switch.
1
. Reconnect MA board CN
70
4
correctly.
Does AV Mute function start/stop,
when closing/opening the shutter?
3. Replace Optical Engine and MAB set.
END
NG
NG
NG
If theAV Mute does not work correctly, apply the
remedy from the top (
1
). If it doesnot work, go on
to the next remedy.
For more information, refer to
4.3.4.2. "Removing the Shutter Switch" (p. 19)
4.4.2 "Removing the Optical Engine
and MAB set(1) (MA Board Assy.) /IF Case" (p. 26)