4-19
EMP-822/EMP-83/EMP-X5/EMP-S5
SEIKO EPSON
Revision:A
4.3.4.2. Removing the Shutter Switch
1. Remove the screw (C.B.P-TITE SCREW,3X8,F/ZN-3C) that secures the Shutter Frame,
and remove the Shutter Frame from the Upper Case Unit carefully not to lose the Shutter
Spring and the Shutter Ball.
2. Remove the following parts from the Upper Case Unit.
•
Shutter Ball
•
Shutter Spring
•
Shutter A
3. Remove the screw (C.P.TYPE1 B-TITET-A.SCREW,2X6,F/ZB-3C) that secures the
Shutter Switch, and remove the Shutter Switch from the Shutter Frame.
Figure 4-12.
When carrying out the following steps, be careful not to lose the Shutter Ball, and
the Shutter Spring.
C.P.TYPE1 B-TITET-
A.SCREW,2X6,F/ZB-3C
Shutter Switch
Shutter Frame
Shutter Ball
Shutter A
Shutter Spring
Upper Case Unit