TROUBLESHOOTING ON OPERATION ABNORMALITY
Error Status
Faulty part/part name
Cause
Remedy
Reference
Operation using Remote Controller
cannot be made.
Remote Controller
Batteries ran out.
Replace the batteries with new ones.
---
Remote Controller is broken.
Replace Remote Controller.
---
Receiver (RC Filter)
The Lower Case or IF Case receiver is
dirty.
Clean Lower Case or IF Case. Replace Lower Case or IF
Case if not improved.
Cable (IR Board)
TH Cable is not connected properly.
Connect the cables of the IR Board to the MA Board
correctly.
TH Cable is broken.
Replace the cables of the IR Board.
IR Board
Elements for remote control processing on
the IR Board are broken. (Circuit error)
If the error continues after carrying out the remedies
above, the circuit on the IR Board is broken, so replace
the IR Board.
IF Board
Elements for remote control processing on
the IF Board are broken. (Circuit error)
If the error continues after carrying out the remedies
above, the related circuit on IF Board is broken, so
replace IF Board.
Projector cannot be operated from the
control panel.
Control panel cable (FFC)
TH Cable is not connected properly.
Connect TH Cable correctly to MA Board.
TH Cable is broken.
Replace the broken TH Cable.
SW Buttons
SW Buttons are broken.
Replace the SW Buttons.
SW Board
SW Board is broken.
Replace the SW Board.
MA Board
Elements for operation processing on MA
Board are broken. (Circuit error)
If the error continues after carrying out the remedies
above, the related circuit on MA Board is broken, so
replace MA Board Assy.
LED does not light up
(Power can be turned on using remote
control.)
SW Board
TH Cable is not connected properly.
Connect the cable to MA Board correctly.
SW Board is broken.
Replace the SW Board.
MA Board
Elements for LED display on MA Board
are broken. (Circuit error)
If the error continues after carrying out the remedies
above, the related circuit on MA Board is broken,
replace MA Board Assy.
AV Mute does not function even if the
shutter is closed.
Lens Shutter Output Switch
TH Cable is not connected properly.
Connect the cable to SW Board correctly.
Lens shutter output switch is broken.
Replace the lens shutter output switch.
Содержание EB-E01
Страница 10: ...INTERNAL USE ONLY C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 22: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 22 Revision A EB FH52 972 982W 992F ...
Страница 23: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 23 Revision A EB W52 ...
Страница 28: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 28 Revision A EB FH52 972 982W 992F ELPMB23 ...
Страница 30: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 30 Revision A EB W52 ELPMB23 ...
Страница 31: ...EB E01 series Product Description INTERNAL USE ONLY SEIKO EPSON 31 Revision A EB W52 ELPMB23 ELPFP13 ELPFP14 ...
Страница 32: ...INTERNAL USE ONLY C H A P T E R 2 TROUBLESHOOTING ...
Страница 63: ...INTERNAL USE ONLY C H A P T E R 3 DISASSEMBLYANDASSEMBLY ...
Страница 170: ...INTERNAL USE ONLY C H A P T E R 4 APPENDIX ...