3.3.12 EX Duct (Assy)
DISASSEMBLY PROCEDURE
1. See
and remove all parts up to the component below from
the projector.
2. Remove the two screws ( ) and the screw ( ), remove the Thermostat of
the "Cable PS-FB" and then remove the "EX Duct (Assy)".
At the area shown below, an electric shock may result if you operate
carelessly because there is electric charge remaining in the Power
Supply.
Pass the cable through the "EX Duct (Assy)" and set the
thermostat of the "Cable PS-FB" such that the surface
with the letters is visible from top to bottom.
EX Duct (Assy)
PS Ballast Assy
C.C.P-TITE SCREW,3X10,F/ZN-3C
C.B.P-TITE SCREW,2.5X10,F/ZN-3C