CHAPTER 4: PERIPHERAL CIRCUITS AND OPERATION (LCD Driver)
I-43
(2) Drive duty
According to the mask option, either 1/4, 1/3 or 1/2
duty can be selected as the LCD drive duty.
Table 4.6.1 shows the differences in the number of seg-
ments according to the selected duty.
Pins Used
Maximum Number
Frame Frequency
in Common
of Segments
(when fosc = 32 kHz)
1/4
COM0–3
80 (20
×
4)
32 Hz
1/3
COM0–2
60 (20
×
3)
42.7 Hz
1/2
COM0–1
40 (20
×
2)
32 Hz
(3) Output specification
➀
The segment pins (SEG0–SEG19) are selected by mask
option in pairs for either segment signal output or DC
output (V
DD
and V
SS
binary output). When DC output
is selected, the data corresponding to COM0 of each
segment pin is output.
➁
When DC output is selected, either complementary
output or Pch open drain output can be selected for
each pin by mask option.
The pin pairs are the combination of SEG (2
*
n) and SEG (2
*
n +
1) (where n is an integer from 0 to 12).
(4) Drive bias
For the drive bias of the E0C6001 or the E0C60L01,
either 1/3 bias or 1/2 bias can be selected by the mask
option.
Table 4.6.1
Differences according to
selected duty
Duty
Note