5.2.2 Bi-D Adjustment
Perform the Bi-D adjustment when you have performed any of the following:
Removing or replacing the printhead unit (See page 70.)
Removing or replacing the printer mechanism (See page 72.)
Replacing the main board assembly (See page 74.)
Removing or replacing the CR motor mechanism (See page 76.)
Removing or replacing the carriage mechanism (See page 78.)
Removing or replacing the ribbon feed mechanism (See page 79.)
Removing or replacing the RPE sensor (See page 80.)
Removing or replacing the BPE sensor (See page 80.)
Removing or replacing the PG sensor (See page 81.)
Removing or replacing the release lever position sensor (See page 81.)
Removing or replacing the PF motor assembly (See page 82.)
Removing or replacing the paper feed mechanism (See page 82.)
Removing or replacing the paper guide (See page 83.)
Follow the instruction shown on the screen of the Adjustment Tool for SIDM to
perform the Bi-D adjustment.
Figure 5-6. Bi-D Adjustment
5.2.3 Top Margin Adjustment
Perform the top margin adjustment when you have performed any of the following:
Replacing the printer mechanism (See page 72.)
Replacing the main board assembly (See page 74.)
Removing or replacing the RPE sensor (See page 80.)
Removing or replacing the BPE sensor (See page 80.)
Removing or replacing the PF motor assembly (See page 82.)
Removing or replacing the paper feed mechanism (See page 82.)
Removing or replacing the paper guide (See page 83.)
Follow the steps below to perform the top margin adjustment.
1. Execute
Pattern Test
.
2. Check the print result, and take action according to the top margin value.
3. Input the top margin value and click
Read
. An adjustment value (8.5 mm) will be
displayed. Click
Input
to save the adjustment value.
The gaps of Bi-D lines must be less than 0.25 mm.
Top margin value
Action
4.9 mm or less
Replace the RPE sensor.
(See page 80.)
5.0
∼
7.4 mm
The top margin adjustment is required. Go to step 3.
7.5
∼
9.5 mm
The top margin is correct and the top margin adjustment is
not required.
9.6
∼
12.5 mm
The top margin adjustment is required. Go to step 3.
12.6 mm or more
Replace the RPE sensor.
(See page 80.)
Содержание cLX-300+II RTP
Страница 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 85: ...C H A P T E R 5 ADJUSTMENT ...
Страница 92: ...C H A P T E R 6 MAINTENANCE ...
Страница 97: ...C H A P T E R 7 LX 300 IIRTP ...
Страница 110: ...APPENDIX ...
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ......