EPSON LX-300+II/300+II RTP/1170II
Revision D
PRODUCT DESCRIPTION
Control codes
32
*4 m2 and m3 apply to the following ID number. (See Table 1-32 & Table 1-33.)
*5 m1=0 to 7 only
<Remote commands>
Table 1-31. Note for Table 1-30
m1 set by AT/CT
m2 set by AT
m3 set by AT
0
0
0
1
All parameters that can be set
Table 1-32. Std and NLSP ver.
m2
m3
Character table
m2
m3
Character table
00H
00H
Italic
19H
00H
BRASCII
01H
00H
PC437
1AH
00H
Abicomp
03H
00H
PC850
7FH
01H
ISO Latin1
07H
00H
PC860
23H
00H
Roman8
08H
00H
PC863
2CH
00H
PC858
09H
00H
PC865
1DH
0FH
ISO 8859-15
18H
00H
PC861
Table 1-33. NLSP ver. only
m2
m3
Character table
m2
m3
Character table
01H
10H
PC437 Greek
20H
00H
Bulgaria
05H
00H
PC853
21H
00H
Hebrew 7
06H
00H
PC855
22H
00H
Hebrew 8
0AH
00H
PC852
24H
00H
PC 774
0BH
00H
PC857
25H
00H
Estonia
0CH
00H
PC862
28H
00H
PC APTEC
0EH
00H
PC866
29H
00H
PC 708
0EH
20H
PC866 LAT.
2AH
00H
PC720
0EH
30H
PC866 UKR
7FH
02H
ISO 8859-2
0FH
00H
PC869
2DH
00H
PC771
0DH
20H
PCAR_864
01H
20H
PC437 Slovenia
1BH
00H
MAZOWIA
2FH
00H
PC MC
1CH
00H
Code MJK
30H
00H
PC1250
1DH
07H
ISO 8859-7
31H
00H
PC1251
1FH
00H
ISO Latin 1T
Table 1-34. Bi-Directional Commands
Function
Code/ Parameter
Save
Set page length
“PG” 05H 00H 00H p1 p2 m1 m2
p1=0(Continuous paper), p2=0(Rear),
p1=1(CSF), p2=0(bin1)
p1=2(Manual insertion), p2=0(Rear)
-Page length=m1+256*m2,
0.118mm (1/216inch)
648 (76.2mm(3inch)) <= m1+256*m2 <=
4752(558.8mm(22 inch))
Set Top margin
“TP” 05H 00H 00H p1 p1 m1 m2
p1=0(Continuous paper), p2=0(Rear),
p1=1(CSF), p2=0(bin1)
p1=2(Manual insertion), p2=0(Rear)
-Top margin=m1+256*m2,
0.118mm (1/216inch)
36 (4.2mm) <= m1+256*m2 <= 288 (8.5mm +
25.4mm(1inch))
Turn unidirectional mode on/
off
“PD” 02H 00H 00H m1
m1=0(Bi-d.), 1(Uni-d.)
Turn auto tear-off on/off
“TO” 02H 00H 00H m1
m1=0(off), 1(on)
Turn auto line feed on/off
“LF” 02H 00H 00H m1
m1=0(off), 1(on)
Select control language
“PM” 02H 00H 00H m1
m1=0(ESC/P), 2(IBM 238x Plus emulation)
Turn printer state reply on/off “ST” 02H 00H 00H m1
m1=0, 1, 2, 3
-
Turn Slash zero on/off
“EX” 06H 00H 00H 00H 00H 00H 01H m1
m1=0(off), 1(on)
Turn Buzzer on/off
“EX” 06H 00H 00H 00H 00H 00H 02H m1
m1=0(enable), 1(disable)
Turn IBM emulation Auto
CR on/off
“EX” 06H 00H 00H 00H 00H 00H 04H m1
m1=0(off), 1(on)
Содержание cLX-300+II RTP
Страница 8: ...C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 42: ...C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 56: ...C H A P T E R 3 TROUBLESHOOTING ...
Страница 65: ...C H A P T E R 4 DISASSEMBLYANDASSEMBLY ...
Страница 85: ...C H A P T E R 5 ADJUSTMENT ...
Страница 92: ...C H A P T E R 6 MAINTENANCE ...
Страница 97: ...C H A P T E R 7 LX 300 IIRTP ...
Страница 110: ...APPENDIX ...
Страница 127: ......
Страница 128: ......
Страница 129: ......
Страница 130: ......