AcuLaser C2800/C2800D/C3800/C3800D
Revision C
TROUBLESHOOTING
Engine-related Trouble FIP
104
Confidential
FIP 1-25 Service Req E300 (Fuser Failure)
Possible parts that caused the error
Troubleshooting
FUSER UNIT
HARNESS ASSY FUSER
HARNESS ASSY LV TOP
LVPS
PWBA MCU
Step
Check
Yes
No
1
Check after turning the power OFF and ON.
Does the error recur even when the power is
turned off and back on again?
Go to Step [2].
End of procedure
2
Check the installation of the FUSER UNIT
Is the FUSER UNIT installed correctly?
Go to Step [3].
Reinstall the
FUSER UNIT.
3
Check the connection of the FUSER UNIT
Check the connection state of the following
items.
FUSER UNIT - PWBA MCU
FUSER UNIT - LVPS
LVPS - PWBA MCU
Are P/J171, P/J17, P/J47, P/J14, and P/J501
connected correctly?
Go to Step [4].
Reconnect
P/J171, P/J17,
P/J47, P/J14, and
P/J501 correctly.
4
Check the continuity of the HARNESS ASSY
FUSER
Is there normal continuity between the
following connectors?
P/J171 <=> P/J17
P/J171 <=> P/J47
Go to Step [5].
Replace the
HARNESS
ASSY FUSER.
5
Check the continuity of the HARNESS ASSY
LV TOP
Is the continuity between P/J14 <=> P/J501
normal?
Go to Step [6].
Replace the
HARNESS
ASSY LV TOP.
Step
Check
Yes
No
6
Check after replacing the FUSER UNIT
Replace the FUSER UNIT with a new one.
Does the error still occur after the replacement?
Go to Step [7].
End of procedure
7
Check after replacing the LVPS
Replace the LVPS with a new one.
Does the error still occur after the replacement?
Replace the
PWBA MCU.
End of procedure
Содержание AcuLaser C2800D
Страница 13: ...Confidential C H A P T E R 1 PRODUCTDESCRIPTION ...
Страница 30: ...Confidential C H A P T E R 2 OPERATINGPRINCIPLES ...
Страница 76: ...Confidential C H A P T E R 3 TROUBLESHOOTING ...
Страница 159: ...Confidential C H A P T E R 4 DISASSEMBLY REASSEMBLY ...
Страница 381: ...Confidential C H A P T E R 5 ADJUSTMENT ...
Страница 389: ...Confidential C H A P T E R 6 MAINTENANCE ...
Страница 395: ...Confidential C H A P T E R 7 APPENDIX ...