4

 

2.2 Optional Accessories 

Remote Meter(Model

MT-5) 

The digital remote meter displays system operating information, error indications, 

and self-diagnostics read-out. Information is displayed on a backlit LCD display. The 

large numerical display and icons are easy to read and large buttons make navigating 

the meter  menus easy.  The meter can be flush mounted in a wall or surface  mounted 

using  the  mounting  frame  (included).  The  MT-5  is  supplied  with  2m  of  cable  and  a 

mounting frame. The MT-5 connects to the RJ45 port on the Tracer. 

3 Installation Instructions 

3.1 General Installation Notes 

Read through the entire installation section first before beginning installation. 

Be very careful when working with batteries. Wear eye protection. Have fresh water 

available to wash and clean any contact with battery acid. 

Uses insulated tools and avoid placing metal objects near the batteries. 

Explosive  battery  gasses  may  be  present  during  charging.  Be  certain  there  is 

sufficient ventilation to release the gasses. 

Avoid  direct  sunlight  and  do  not  install  in  locations  where  water  can  enter  the 

controller. 

Loose  power  connections  and/or  corroded  wires  may  result  in  resistive  connections 

that  melt  wire  insulation,  burn  surrounding  materials,  or  even  cause  fire.  Ensure 

tight  connections  and  use  cable  clamps  to  secure  cables  and  prevent  them  from 

swaying in mobile applications. 

Use with Gel, Sealed or Flooded batteries only. 

Battery connection may be wired to one battery or a bank of batteries. The following 

instructions  refer  to  a  singular  battery,  but  it  is  implied  that  the  battery  connection 

can be made to either one battery or a group of batteries in a battery bank. 

 Select the system cables according to 3A/mm

2

 current density. 

3.2 Mounting 

NOTE: When  mounting the  Tracer, ensure free air through  the controller  heat 

sink  fins.  There  should  be  at  least  150mm  of  clearance  above  and  below  the 

controller to allow for cooling. If mounted in an enclosure, ventilation

 

is highly       

                            recommended.

 

WARNING: Risk of explosion! Never install the Tracer in a sealed enclose with 

flooded batteries! Do not install in a confined area where battery gas 

 

                         

can accumulate. 

Содержание Tracer-1206RN

Страница 1: ...ting our product This manual offers important information and suggestions with respect to installation use and troubleshooting etc Please read this manual carefully before using the product and pay at...

Страница 2: ......

Страница 3: ...Max PV Input Voltage Tracer 1206RN 60VDC Tracer 1210RN 100VDC Tracer 1215RN 150VDC Max PV Input Power 12V System 130W 24V System 260W Array voltage should never exceed maximum PV input voltage Refer t...

Страница 4: ...3 1 General Installation Notes 4 3 2 Mounting 4 3 3 Wiring 5 4 Operation 10 4 1 MPPT Technology 10 4 2 Battery Charging Information 11 4 3 LED Indications 13 4 4 Setting Operation 16 5 Protections Tr...

Страница 5: ...for safe and proper operation of the controller NOTE Indicates a procedure or function that is important for the safe and proper operation of the controller General Safety Information Read all of the...

Страница 6: ...ent thermal design and nature air cooling RJ45 interface with remote meter MT 5 convenient to check operating parameters of controllers The Tracer series controller is for off grid solar system and co...

Страница 7: ...system errors 4 Setting Indicator Corresponding indicator will be on when set timer1 timer2 and battery type 5 LED Digital Display Display the load work mode and status 6 Setting Button in manual mod...

Страница 8: ...entilation to release the gasses Avoid direct sunlight and do not install in locations where water can enter the controller Loose power connections and or corroded wires may result in resistive connec...

Страница 9: ...ur 4 mounting hole locations on the mounting surface Step 4 Drill Holes Remove the controller and drill four sizeable holes in the marked locations Step 5 Secure Controller Place the controller on the...

Страница 10: ...ARNING Risk of explosion or fire Never short circuit battery positive and negative or cables Figure 3 2 Battery wiring Before connecting the battery measure the battery voltage It must be over 9V to p...

Страница 11: ...s time Confirm the connection correct and then turn on the power If wiring the load connection to a load distribution panel each load circuit should be fused separately The total load draw should not...

Страница 12: ...Refer to the instructions provided for detailed installation procedures Step 5 Confirm Wiring Double check the wiring in step1 through 4 Confirm correct polarity at each connection Verify that all si...

Страница 13: ...firm Power up When battery power is applied and the Tracer powers up the battery led indicator will be green If the Tracer does not power up or battery status LEDs error exists refer to Section 5 Trou...

Страница 14: ...is true 1 Power Into the Tracer Power Out of the Tracer 2 Volts In Amps In Volts Out Amps Out Assuming 100 efficiency Actually the losses in wiring and conversion exist If the solar module s Vmp is gr...

Страница 15: ...d energy compared to traditional controllers Conditions That Limits the Effectiveness of MPPT The Vmp of a solar module decreases as the temperature of the module increases In very hot weather the Vmp...

Страница 16: ...ery is fully recharged there will be no more chemical reactions and all the charge current transmits into heat and gas at this time Then the Tracer reduces the voltage to the floating stage charging w...

Страница 17: ...specific requirements of the battery used in the system Certain types of batteries benefit from periodic equalizing charge which can stir the electrolyte balance battery voltage and complete chemical...

Страница 18: ...range GREEN FLASHING when battery full ORANGE ON when battery under voltage RED ON when battery over discharged Please refer to Chapter 5 for troubleshooting Battery LED indicator Table 4 2 Color Indi...

Страница 19: ...gital tube displays C PV Overcurrent Load indicator When the load amp is 1 25times of rated current for 60 seconds or the load amp is 1 5 times of rated current for 5 seconds overload or load short ci...

Страница 20: ...hold Voltage the solar controller will recognize the starting voltage and turn off the load after 10 minutes delay 2 Light ON Timer 1 15h on When solar module voltage goes below the point of NTTV Nigh...

Страница 21: ...pe When timer 1 setting indicator is on press the setting button for more than 5 seconds till the LED digital tube flashes Then press the setting button till the desired number appears according to th...

Страница 22: ...minutes delay since sunset 6 Load will be on for 7 hours after ten minutes delay since sunset 7 Load will be on for 8 hours after ten minutes delay since sunset 8 Load will be on for 9 hours after te...

Страница 23: ...on for 11 hours before sunrise 11 Load will be on for 12 hours before sunrise 12 Load will be on for 13hours before sunrise 13 Load will be on for 14 hours before sunrise 14 Load will be on for 15 hou...

Страница 24: ...ng short circuit After one automatic load reconnect attempt the fault must be cleared by reapply power or pressing the setting button PV Reverse Polarity Fully protection against PV reverse polarity n...

Страница 25: ...r cut off the output automatically LED indicator will return to green automatically when fully charged LED digital tube displays P PV Overvoltage Check whether the PV parameters match with the control...

Страница 26: ...rnt wire connections Check and confirm that LED digital tube is consistent with required Pay attention to any troubleshooting or error indication Take necessary corrective action Confirm that all the...

Страница 27: ...of date and place of purchase To obtain rapid service under this warranty the returned products must include the model serial number and detailed reason for the failure the module type and size type o...

Страница 28: ...g Gel Sealed Flooded High Volt Disconnect 16V x2 24V 16V x2 24V 16V x2 24V Charging limit voltage 15 5V x2 24V 15 5V x2 24V 15 5V x2 24V Over Voltage Reconnect 15V x2 24V 15V x2 24V 15V x2 24V Equaliz...

Страница 29: ...float and low voltage disconnect voltage Environmental Parameters Environmental Parameter Ambient temperature range 35 to 55 Storage temperature range 35 to 80 Humidity range 10 90 NC Enclosure IP30...

Страница 30: ...r 1210RN 1 Solar Module MPP Voltage 17V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V Nominal System Voltage 12V 92 0 92 5 93 0 93 5 94 0 94 5 95 0 95 5 96 0 10 20 30 40 50 60 70 80 90 100...

Страница 31: ...ltage 12V 4 Solar Module MPP Voltage 34V Nominal System Voltage 24V 81 0 83 0 85 0 87 0 89 0 91 0 93 0 95 0 10 20 30 40 50 60 70 80 90 100 110 120 130 93 5 94 0 94 5 95 0 95 5 96 0 96 5 97 0 97 5 20 4...

Страница 32: ...5 Solar Module MPP Voltage 68V Nominal System Voltage 24V 88 0 89 0 90 0 91 0 92 0 93 0 94 0 95 0 96 0 97 0 20 40 60 80 100 120 140 160 180 200 220 240 260 W...

Страница 33: ...Tracer Dimensions mm Tracer 1206RN 1210RN 1215RN...