15
Press the setting button once and setting indicators will be changed once
among load 1, load 2 and battery type.
When load 1 setting indicator is on, press the setting button for more than 5
seconds till the LED digital tube flashes. Then press the setting button till the
desired number appears according to the following table. The setting is
finished when the digital tube stop flashing.
Setting work mode of load 2 is the same as load 1 when the load2 timer is
on.
Load work mode Table 4-5
Load Work mode
LED
digital
No.
Disable
n
Dusk to Dawn, Load will be on all night
0
Load will be on for 1 hour after ten minutes delay since sunset
1
Load will be on for 2 hours after ten minutes delay since sunset
2
Load will be on for 3 hours after ten minutes delay since sunset
3
Load will be on for 4 hours after ten minutes delay since sunset
4
Load will be on for 5 hours after ten minutes delay since sunset
5
Load will be on for 6 hours after ten minutes delay since sunset
6
Load will be on for 7 hours after ten minutes delay since sunset
7
Load will be on for 8 hours after ten minutes delay since sunset
8
Load will be on for 9 hours after ten minutes delay since sunset
9
Load will be on for 10 hours after ten minutes delay since sunset
10
Load will be on for 11 hours after ten minutes delay since sunset
11
Load will be on for 12 hours after ten minutes delay since sunset
12
Load will be on for 13hours after ten minutes delay since sunset
13
Load will be on for 14 hours after ten minutes delay since sunset
14
Load will be on for 15 hours after ten minutes delay since sunset
15
Test mode
16
ON/OFF mode
17