4.5.1 Real time adjustment 

 

When LCD displays time to be adjusted:: Press K3 for two times 
and display 

“SET” 

 

Press K1 or K2 to change the year, month and day automatic and 
circlely 

 

Press K3, 

“SET” flashing, and modify the data by K1 and K2, note: 

only the last two numbers can be modified. 

 

Press K3 to confirm the modification and save the data; Press K4 
to  cancel  the  modification  and  return  to  the  second  step,  and 
“SET” stop flashing. 

  Press  K4  two  times  and  return  to 

“reading  status”,  year,  month, 

day, hour:minute will repeat in display ever 3 seconds.

 

 

 

4.5.2

 Li hours ON

” time adjustment 

 

 

When LCD displays time to be adjusted:: Press K3 for two times 
and display 

“SET” 

 

Press K1 to display 

“on hours” see following: 

 

 

 

 

Press K3 for one time and 

“SET” flash 

 

Modify the hours between 1~12 by K1 and K2 

 

Press K3 to confirm the modification and save the data; Press K4 
to  cancel  the  modification  and  return  to  the  second  step,  and 
“SET” stop flashing. 

 

Press K4 for one time and turn to 

“reading status” 

 

4.5.3

”Exact time” adjustment 

 

 

When LCD displays time to be adjusted:: Press K3 for one time 
and turn to reading status for time. 

 

Press K1,K2 and turn to the    months of the first season. 

 

Press K3 for one time and turn to the reading status for the first 
season. 

 

Press  K1,K2,  and  will  display  the  months  of  first  season,  ON  1 
and OFF 1, ON 2 and OFF 2, the arrowhead of the below picture 
shows the display order.   

 

Press K

3, “SET” and H of H:M flashes, user can modify hours by 

K1,K2 

 

  Press  K3  to  confirm  the  modification  and  save  the  data,  and 
return to the fourth step; Press K4 to cancel the modification and 
return to the fourth step, and 

“SET” stop flashing. 

 

When modify Hour and Minute, H will be modified first. Press K3 and turn 
to M modification. Press K3 again, confirm the modification and save the 
data, and return to the fourth step; Press K4 to cancel the modification and 
return to the fourth step, and 

“SET” stop flashing. 

 

Press K4 for two times, and turn to reading status. 

The default time data is 0, and the controller will follow the last data setting. 
 

The modification for the last month of the first season: 

 

When  displaying  the  first  season,  press  K3  for  one  time  and 
“SET” flashing; 

 

Adjust data for month between 1~12 by K1-K2 

 

Press K3 to confirm or Press K4 to cancel. 

“SET “ stop flashing, 

return to the fourth step above. 

Modification for H and M: 

 

When LCD displays time to be adjusted: 

Press K3, “SET” and H 

of H:M flashes, user can modify hours 

 

User can adjust data 0~23 by K1/K2

 

 

Press  K3  again,  save  data  of  hours  and  then  turn  to  modify 
minute, “SET” and M of H:M flashes.

 

 

User can adjust data 0~59 by K1/K2.

 

 

Press K3 and save the modified data, if not saved, then press K4 
to return select status-

“SET” not flash.

 

Note: the EXACT TIME Control can be divided to 4 seasons, for example: 

 

1 is the season no. 3 is the last month of season.   

Customers  can  also  set  1-12,  that  means  the  whole  year  will  have  one 

season, and the controller will work same during the whole season. 

 

 

 

 

 

 

 

 

Содержание EPIP20-LT Series

Страница 1: ...t equalizing float charging Four work mode ON OFF lighting control Lighting hours on ON OFF exact time Protecting Function TVS lighting protecting Over load short circuit polarity reverse protection electronic fuse Display LCD display specially designing for solar system LCD display all system parameters in digital value system status as symbols Accurate clock show 2 Controller panel instructions ...

Страница 2: ...tems does not function properly if this sequence order is not followed An improper sequence order can damage the battery 5 The parameters can be set depending on the user s need 6 The negative battery is grounded or ground connected as the above 4 Operation instructions 1 Keys instructions from left to right K1 Reading status switch to next figure Setting status switch to next function or increase...

Страница 3: ... Operation instructions 4 1 Reading specifications On reading status press K1 K2 LCD will repeat the following specifications 4 3Battery capacity modify While display battery capacity XXXX AH press K3 into setting mode battery unit AH SET is flashing modify the data through K1 K2 press one time battery capacity will be up down 10 the maximum is 5000 the minimum is 50 Press K3 for saving or K4 for ...

Страница 4: ...ws the display order Press K3 SET and H of H M flashes user can modify hours by K1 K2 Press K3 to confirm the modification and save the data and return to the fourth step Press K4 to cancel the modification and return to the fourth step and SET stop flashing When modify Hour and Minute H will be modified first Press K3 and turn to M modification Press K3 again confirm the modification and save the...

Страница 5: ...on 1 25 times of Ie for 60secs 1 5 times of Ie by for 5secs overload protection 3 time of Ie short circuit protection Self consumption Control mode 15 mA LED LCD display 15mA Total 30mA System voltage 12 24V AUTOWORK Work temperature industrial 20 to 70 Battery capacity Battery in parallel from 50AH to 5000ah Boost charging 14 8V 2 24V equalizing charging voltage 14 4V 2 24V Float charging 13 6V 2...

Отзывы: