Front Panel Operation
Operating Mode description
UI Mode
In UI mode, the set values for voltage and current are transferred directly to the switch mode regulator. There is no
additional digital control.
UIP Mode
In UIP mode, the set values
for voltage and current are transferred directly to the switch mode regulator. If the output
current exceeds the previously adjusted limit value, the current set point will be regulated.
UIR Mode
In UIR mode, the voltage set point is regulated in a way that a power supply unit with (adjustable) internal resistance
is simulated. The set value for current limiting is transferred directly to the switch mode regulator.
PV
sim
Mode
In PV
sim
mode, the diagram of a PV generator is simulated. Given values are open-circuit voltage U
o
, short-circuit
current I
k
, as well as the amounts of voltage and current by which the PV generator delivers the maximum power
(U
mpp
, I
mpp
). Parameters can be found in the specification sheet of the simulated PV generator.
Values for U
mpp
may be in a range from 0.6 to 0.95
*
U.
Values for I
mpp
may be in a range from 0.6 to 0.95
*
I.
Script Mode
In script mode, the unit is controlled by memory card. The display status ‚
Mode
‘ shows the present operating mode
‚UI‘
. The lower right corner of the display shows the word
‚Scr‘
, which indicates that script operation was selected. If
there is no memory card in the slot, this option cannot be selected. For detailed information about memory card
control and about how to build up a script, see
Script Control
.