© EPS Stromversorgung in 2022, this information is subject to change without notice
49
30000800_manual_psb_10000_4u_30kw_en_04
3.5.3.1
Sub menu “Settings”
This sub menu can be accessed directly from the main screen by tapping the Settings button.
Group
Parameters & description
Presets
U, I, P, R
Presetting of all set values via on-screen numeric pad.
Protection
OVP, OCP, OPP
Adjust the thresholds of the protections
Limits
U-max, U-min etc.
Define the adjustment limits (find more information in
User events
UVD, OVD etc.
Define supervision thresholds which can trigger user defined events (find more information in
General
Allow remote control
If remote control is allowed, the device can’t be controlled remotely over either the digital or analog
interfaces. This situation will be shown as “Local” in the status area on the main display. Also see sec-
tion
R mode
Activates or deactivates the internal resistance control. If activated, the resistance set value and actual
will be shown the main screen. For details refer to
“3.3.4. Internal resistance regulation (source mode)”
and
“3.5.6. Manual adjustment of set values”.
Voltage controller speed
(Switching the speed only works if the device has already been delivered with firmware KE 3.02 or
higher)
This switch can be used to select the internal voltage controller speed which, as a result, impacts
possible system oscillation. For more information refer to
“3.3.7. Dynamic characteristics and stability
•
Slow
= the voltage controller will be a little slower, the oscillation tendency will decrease
•
Normal
= the voltage controller is on standard speed (Default)
•
Fast
= the voltage controller will be a little faster, the oscillation tendency will increase
SEMI F47
(Only displayed if the device has already been delivered with firmware KE 3.02 or higher)
Activates or deactivates a feature called SEMI F47 which is related to the equally named standard. See
“3.12.3. SEMI F47” for more information.
Analog interface Range
Selects the voltage range for the analog set values, actual values and reference voltage output.
•
0...5 V
= Range is 0...100% for set /actual values, reference voltage will be 5 V
•
0...10 V
= Range is 0...100% for set /actual values, reference voltage will be 10 V
Also see
“3.6.4. Remote control via the analog interface”
REM-SB Level
Selects how the input pin REM-SB of the analog interface shall be working regarding levels (see
“3.6.4.3. Analog interface specification”
) and logic:
•
Normal
= Levels and function as described in the table in
•
Inverted
= Levels and function will be inverted
Also see