Introduction

Thank you for purchasing your eSoft Pro Water Softener. The Clack CI valve with which your water 

softener is fi tted has been selected to provide the best effi  ciency & performance possible. 

Only 

attempt this installation if you have been trained on the installation of water softeners.

  

Packing List

Your water softener comprises of:

Assembled eSoft Water Softener
Transformer
 ¾” quick connect fi ttings
Overfl ow adaptor

Installation Instructions

Firstly, the area needs to be level, have access to electricity and an open drain. Your water softener has 

been designed to operate between 1.7 and 5 bar pressure. If your water pressure falls outside these 

parameters it may be necessary to fi t a booster pump or a pressure reducing valve to prevent damage 

to the unit. The operating temperature range of the appliance is 3°C and 45°C. Follow the instructions 

supplied to connect the ¾” quick connect fi ttings.

Please observe local regulations concerning the installation of your system. Check that you have 

allowed space for access to the unit for possible future maintenance. This installation may require 

plumbing work and will require an electrical outlet to be fi tted near the system. If the system is 

installed externally, take necessary precautions to prevent frost damage.

Inlet:

 This is the water supply from the mains or other.  Always 

install a suitable prefi lter on well water supplies. 

Outlet

:

 This is the softened water leaving the softener to 

supply the rest of the house.

Drain:

This is the water used during regeneration which is 

fl ushed to drain. This water will be at mains pressure and must 

be taken directly to a waste-pipe with an air gap.

Overfl ow:

This is used in the event of an over-fi ll of water 

to the salt cabinet. This should always be taken directly to 

a waste-pipe with an air gap.  Install the supplied overfl ow 

fi tting by drilling a 20mm hole. Its recommended to install the 

overfl ow 2-3 inches below the salt lid of the cabinet.

Introduction

Thank you for purchasing your eSoft Water Softener. The Clack CI valve with which your water softener 

is fitted has been selected to provide the best efficiency & performance possible. 

Only attempt this 

installation if you have been trained on the installation of water softeners.

  

Packing List

Your water softener comprises of:

Assembled eSoft Water Softener
Transformer
 ¾” quick connect fittings
Installation Manual 
Overflow adaptor

Installation Instructions

Firstly, the area needs to be level, have access to electricity and an open drain. Your water softener 

has been designed to operate between 1.7 and 5 bar pressure. If your pressure falls outside these 

parameters it may be necessary to fit a booster pump or a pressure reducing valve to prevent damage 

to the unit. The operating temperature range of the appliance is 3°C and 45°C. Follow the instructions 

supplied to connect the ¾” quick connect fittings.

Please observe local regulations concerning the installation of your system. Check that you have 

allowed space for access to the unit for possible future maintenance. This installation may require 

plumbing work and will require an electrical outlet to be fitted near the system. If the system is 

installed externally, take necessary precautions to prevent frost damage.

Inlet:

 This is the water supply from the mains or other.  Always 

install a suitable prefilter on well water supplies. 

Outlet

:

 This is the softened water leaving the softener to 

supply the rest of the house.

Drain:

 

This is the water used during regeneration which is 

flushed to drain. This water will be at mains pressure and must 

be taken directly to a waste-pipe with an air gap.

Overflow:

 

This is used in the event of an over-fill of water 

to the salt cabinet. This should always be taken directly to 

a waste-pipe with an air gap.  Install the supplied overflow 

fitting by drilling a 20mm hole. Its recommended to install the 

overflow 2-3 inches below the salt lid of the cabinet.

1.
2.
3.
4.
5.

1.
2.
3.
4.

Содержание eSoft Pro

Страница 1: ...Water Softener Installation Manual ...

Страница 2: ...e Its recommended to install the overflow 2 3 inches below the salt lid of the cabinet Introduction Thank you for purchasing your eSoft Water Softener The Clack CI valve with which your water softener is fitted has been selected to provide the best efficiency performance possible Only attempt this installation if you have been trained on the installation of water softeners Packing List Your water ...

Страница 3: ...t the day override preset at 4 Press Next Set the regeneration time preset at 2am 1 2 3 4 5 6 7 8 Commissioning your water softener With the softener now programmed press hold Regen until the motor begins to turn When the motor stops the screen will appear as in Fig 4 Now open the inlet valve slowly to allow the softener fill with water At this point water will discharge to the drain and purge any...

Страница 4: ...Certified Valve Up to 4 people Volumetric Water Softener Intelligent Controls 10L Cabinet Water Softener by eS ft PRO 1 Pressure Reducing Valve Raw water sample point Inlet pressure Bypass Backwash water pipe minimum Drain with air gap Treated water sample point Outlet pressure 2 3 4 5 6 Recommended extra bypass 7 assembly for servicing Pre Filter eSoft PRO 10L By EPS Assembly Installation C M Y C...

Страница 5: ...0mm 240mm 350mm Maximum working pressure 5 bar 5 bar 5 bar 5 bar Minimum working pressure 1 7 bar 1 7 bar 1 7 bar 1 7 bar Service flow rate 10L min 10L min 15L min 23L min Pressure drop at service flow 0 2 bar 0 2 bar 0 35 bar 0 55 bar Resin Volume 5 litres 8 litres 20 litres 30 litres Minimum supply flow rate 5L min 8L min 8L min 8L min Salt use per regeneration 0 75 kgs 1 2 kgs 3 0 kgs 4 5 kgs I...

Отзывы: