PSB 9000 3U Slave Series
15 kW
Model Slave
PSB 9500-90
PSB 9750-60
PSB 91000-40
PSB 91500-30
AC Input
Voltage range (L-L), frequency
342..528 V AC
Connection
3ph, PE
3ph, PE
3ph, PE
3ph, PE
Frequency range
45 - 65 Hz
45 - 65 Hz
45 - 65 Hz
45 - 65 Hz
Fusing (internal)
6x T16 A
6x T16 A
6x T16 A
6x T16 A
Leak current
< 3.5 mA
< 3.5 mA
< 3.5 mA
< 3.5 mA
Phase current
> 0.99
> 0.99
> 0.99
> 0.99
Efficiency of energy recovery
≤ 94.5%
≤ 94.5%
≤ 93.5%
≤ 94.5%
DC terminal
Max. voltage U
Max
500 V
750 V
1000 V
1500 V
Max. current I
Max
90 A
60 A
40 A
30 A
Max. power P
Max
15 kW
15 kW
15 kW
15 kW
Overvoltage protection range
0...550 V
0...825 V
0...1100 V
0...1650 V
Overcurrent protection range
0...99 A
0...66 A
0...44 A
0...33 A
Overpower protection range
0…16.5 kW
0…16.5 kW
0…16.5 kW
0…16.5 kW
Temperature coefficient for set
values Δ/K
Voltage / current: 100 ppm
Capacitance (approx.)
540 μF
540 μF
130 μF
60 μF
Voltage regulation (general)
Adjustment range
0...510 V
0...765 V
0...1020 V
0...1530 V
Accuracy
(1
(at 23 ± 5°C)
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
< 0.1% U
Max
Line regulation at ±10% ΔU
AC
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
< 0.02% U
Max
Remote sensing compensation
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Max. 5% U
Max
Voltage regulation (power supply)
Load regulation at 0...100% ΔI
OUT
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Rise time 10...90%
ΔU
OUT
Max. 30 ms
Max. 30 ms
Max. 30 ms
Max. 30 ms
Transient time after ΔI
OUT
< 1.5 ms
< 1.5 ms
< 1.5 ms
< 1.5 ms
Ripple
(2
< 350 mV
PP
< 70 mV
RMS
< 800 mV
PP
< 200 mV
RMS
< 1600 mV
PP
< 300 mV
RMS
< 2400 mV
PP
< 400 mV
RMS
Voltage regulation (el. load)
Load regulation at 0...100% ΔU
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
< 0.05% U
Max
Current regulation (general)
Adjustment range
0...91.8 A
0...61.2 A
0...40.8 A
0...30.6 A
Accuracy
(1
(at 23 ± 5°C)
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
< 0.2% I
Max
Line regulation at ±10% ΔU
AC
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
< 0.05% I
Max
Current regulation (power supply)
Load regulation at 0...100% ΔU
OUT
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Current regulation (el. load)
Load regulation at 0...100% ΔU
IN
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
< 0.15% I
Max
Ripple
(2
< 48 mA
RMS
< 48 mA
RMS
< 16 mA
RMS
< 26 mA
RMS
(1 Related to the nominal values, the accuracy defines the maximum deviation between an adjusted values and the true (actual) value.
Example: a 80 V model has min. 0.1% voltage accuracy, that is 80 mV. When adjusting the voltage to 5 V, the actual value is allowed to differ max. 80 mV, which
means it might be between 4.92 V and 5.08 V.
(2 RMS value: LF 0...300 kHz, PP value: HF 0...20MHz