background image

13 

4.

 If you choose the palm, 

repeat step 1-3 to obtain a 
drop of blood sample.

 

5. 

Press the trigger button to 

activate the lancing device. 

6. 

Hold the device against 

forearm or palm and increase 
pressure until the blood sample 
size is sufficient 

 

 

 

Running A Blood Glucose Test With Blood From Your Forearm (continued)

 

Содержание EG V1(BL)

Страница 1: ...1 EG V1 BL Self Monitoring Blood Glucose System Quick Reference Guide...

Страница 2: ...emory 1 Press X until turning the meter on Press W once again and release to enter the setting mode 2 The last 2 digits of the year flash at the center of the display Press X to adjust the year and Pr...

Страница 3: ...W to confirm the setting 5 Press X to adjust value of hype and Press W to confirm the setting 6 When setting is finished the display will be back to the testing mode of flashing strip Hypo setting are...

Страница 4: ...display will show no CODE the first time batteries are installed 2 Insert the code card into the slot The screen displays OK 3 The code number will be shown on the display Make sure the code number o...

Страница 5: ...ueeze the bottle until a tiny drop forms at the tip of the bottle Touch the drop to the Blood collection area at the end of the test strip Do not put control solution on top of the test strip When you...

Страница 6: ...y Don t remove the test strip yet Check if the reading falls within the range printed on the test strip bottle 7 Remove the test strip and throw it away after you have compared the reading to the rang...

Страница 7: ...Lancet Into The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing device firmly then twist off the pr...

Страница 8: ...8 Select 1 3 for soft or thin skin 4 5 for average and 6 8 for thick or calloused skin 3 Recap the front cap 4 Select the desired penetration depth...

Страница 9: ...ding barrel of the lancing device until it clicks and then release Now the lancing device is ready Do not prick your finger until your meter and strip are prepared 6 Set the lancing device aside until...

Страница 10: ...The meter turns on 3 Swab the blood collection area on your finger with an alcohol swab Please wait at least 5 seconds until the intended area is dry and clean before sampling the blood 4 Place the l...

Страница 11: ...ip Do not put blood on top of the strip Be sure to get enough blood on the strip s reaction zone Otherwise an inaccurate reading may result 7 The meter will beep when enough blood has entered the stri...

Страница 12: ...clear adjustable tip against the forearm 1 This graphic shows where the meter cleared for alternative site testing Running A Blood Glucose Test With Blood From Your Forearm Check with your healthcare...

Страница 13: ...a drop of blood sample 5 Press the trigger button to activate the lancing device 6 Hold the device against forearm or palm and increase pressure until the blood sample size is sufficient Running A Blo...

Страница 14: ...le lancets according to the recommendations of your healthcare professional 1 Unscrew and remove the adjustable cap Without touching the used lancet stick the lancet tip into its protective cover Grip...

Страница 15: ...Press W to view the previous results in order from the latest to the earliest 3 Press X once again to view averages of 7 day test result 4 Press W to review averages of 14 day 30 day and 90 day test r...

Страница 16: ...of alarm 2 Press W to set On for the first alarm 3 Press W to adjust time and press X to confirm the setting 24 hour clock 4 Press X to confirm the first setting and then get into the second one 5 Re...

Страница 17: ...n error message If you have any concerns please contact your local dealer System fault Action Replace the batteries first If 001 ERROR appears again please contact your local dealer Humidified Used st...

Страница 18: ...tion with temperature between 10 C 40 C 50 F 104 F The Lt and thermometer icon appears Temperature is too low outside the required range of 10 C 40 C 50 F 104 F This alerts users that an incorrect res...

Страница 19: ...contact your healthcare professional The test result is lower than 20 mg dL Action Test again If the result is still the same please contact your healthcare professional Err message Not enough sample...

Страница 20: ...3 6686866 E mail info epsbio com tw Website http www epsbio com tw Reference American Diabetes Association Standards of Medical Care for Patients with Diabetes Mellitus Diabetes Care 25 2002 p S37 05...

Отзывы: