background image

 

 
 
 

EasyPlus mini R13N 

Self-Monitoring Blood Glucose System 

 
 

Quick Reference Guide

 

 

 

 

Содержание EasyPlus mini R13N

Страница 1: ...EasyPlus mini R13N Self Monitoring Blood Glucose System Quick Reference Guide ...

Страница 2: ...lood Glucose Meter is set at mg dL without any modification function 3 Repeat step 2 to set the date and time The flashing field is the one you are currently setting 1 Put a battery into the slot and the meter turns on automatically 2 The last 2 digits of the year flash at the center of the display Press to adjust the year and press to confirm the setting ...

Страница 3: ...cap and wipe the tip of the bottle with a tissue 1 If display stays at or and no any setting is made the test results will always in or 2 If you do not choose CtL the test results will be included in the memory of blood test 1 Put a test strip into the meter in the direction of the arrow and the icon of shows itself 2 Press twice to set CtL and press to confirm the setting ...

Страница 4: ...8 When you hear the beeper you have enough control solution in the test strip The meter starts to count down from 5 seconds and will show the results 9 A result appears on the display Don t remove the test strip yet Check if the reading falls within the range printed on the test strip bottle 10 Remove the test strip and throw it away after you have compared the reading to the range printed on the ...

Страница 5: ...ncet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing device firmly then twist off the protective cover 3 Recap the front cap Lancets are for use only and a new sterile lancet should be used each time you perform a test ...

Страница 6: ...lancing devices and lancets may transmit blood borne pathogens such as viral hepatitis 6 Set the lancing device aside until later in the test 5 Pull on the sliding barrel of the lancing device until it clicks and then release Now the lancing device is ready Do not prick your finger until your meter and strip are prepared 4 Select the desired penetration depth ...

Страница 7: ...nd warm water Rinse and dry thoroughly 4 When the blood drop flashes on the display obtain a drop of blood from your fingertip using the lancing device 2 Insert a test strip into the meter in the direction of the arrow and the icon will appear 3 Press to set or and press to confirm the setting ...

Страница 8: ...rop Touch the blood drop to the tip of the transparent window of the test strip Do not put blood on top of the strip Be sure to get enough blood on the strip s reaction zone Otherwise an inaccurate reading may result 7 The meter will beep when enough blood has entered the strip s reaction zone The result will appear on the display after 5 seconds 8 Remove the test strip and the meter turns off aut...

Страница 9: ...essure until the blood sample size is sufficient Running a Blood Glucose Test with Blood From Your Forearm Optional Please use the clear cap with the lancing device for AST testing 1 Massage the puncture area of forearm for a few seconds 2 Press and hold the device with clear adjustable tip against the forearm ...

Страница 10: ...te the lancing device 4 Hold the device against palm and increase pressure until the blood sample size is sufficient 1 Massage the puncture area of palm for a few seconds Running a Blood Glucose Test with Blood From Your Palm Optional Check with your healthcare professional before testing other sites than fingertip ...

Страница 11: ...the cap 2 Without touching the used lancet stick the lancet tip into its protective cover 3 Pointing the lancing device toward a container for sharp or biohazard material slide the ejection button down to release the covered lancet into the container ...

Страница 12: ...a test strip 1 Press to review test results of 30 days in or 2 Press to review all results in order from records of 360 to 001 3 To delete a test result press for 3 seconds and display shows dEL 4 Press to keep reviewing test results 5 The meter will turn off in 1 minute automatically ...

Страница 13: ...w them at any time without inserting a test strip 1 Press to review test results of 30 days in or 2 Press to review results of 7 14 30 60 or 90 days 3 Press to go back the display of 4 Meter will turn off in 1 minute automatically ...

Страница 14: ...your local dealer or healthcare provider Message What it means What to do Humidified Used strips The meter has detected a problem with the test strip Repeat the test with a new strip Refer to pages 7 8 for information on sample application Low power The meter batteries do not have enough power to perform a test Replace the new batteries ...

Страница 15: ...rst If Err 001 appears again please contact your local dealer The test result is among 20 60 mg dL Please call your healthcare professional The test result is higher than 630 mg dL Re check your glucose level If the result is HI again obtain and follow instructions from your healthcare professional without delay ...

Страница 16: ...emperature is too high outside the required range of 10 C 40 C 50 F 104 F This alerts users that an incorrect result may occur if the test continues Relocate the meter to a location with temperature between 10 C 40 C 50 F 104 F The Lt and thermometer icon appears Temperature is too low outside the required range of 10 C 40 C 50 F 104 F This alerts users that an incorrect result may occur if the te...