1. 

Massage the puncture area 

of palm or forearm for a few 
seconds. 

2. 

Press and hold the device 

with clear adjustable tip 
against the forearm.

 

3. 

Press the trigger button to 

activate the lancing device. Hold 
the device against forearm and 
increase pressure until the blood 
sample size is sufficient. 

Running A Blood Glucose Test With Blood From Your Palm and Forearm

   

Please use the clear cap with the lancing device for AST testing.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Содержание EasyMax Voice III

Страница 1: ...1 EasyMax Voice III Self Monitoring Blood Glucose System Quick Reference Guide...

Страница 2: ...pen the battery door on the back of the meter by pushing the tab in the direction of the arrow and pulling the door up 2 Insert two batteries You will hear opening music 3 Put the battery door back in...

Страница 3: ...on to select ES En English ES Espa ol 2 And press power button to confirm the setting 3 Repeat step 1 and 2 to set the volume 1 The priority language of the blood glucose meter is set in English 2 The...

Страница 4: ...te in your meter is important if you intend to use the meter memory 1 Press M button and C button to set the year Press power button to confirm the setting 2 Repeat step 1 to set the date 3 Repeat ste...

Страница 5: ...a flat surface like a table 4 Remove the control solution bottle cap and wipe the tip of the bottle with a tissue 5 Squeeze the bottle until a tiny drop forms at the tip of the bottle 2 The meter turn...

Страница 6: ...within the range printed on the test strip bottle 9 Press power button to repeat the test result Or you can also press C button or M button to set the volume before repeating the result 10 Remove the...

Страница 7: ...The Lancing Device You must first load the lancet into the lancing device to get it ready for use 1 Unscrew the Cap 2 Insert the lancet into the lancing device firmly then twist off the protective co...

Страница 8: ...average and 4 5 for thick or calloused skin 6 Set the lancing device aside until later in the test 5 Pull on the sliding barrel of the lancing device until it clicks and then release Now the lancing d...

Страница 9: ...ing 3 When the blood drop flashes on the display the meter will tell the instruction Running A Blood Glucose Test With Blood From Your Fingertip 1 Wash your hands with soap and warm water Rinse and dr...

Страница 10: ...indow Otherwise an inaccurate reading may result 7 The meter starts to count down from 5 seconds and speaks the result 8 Press power button to repeat the test result Or you can also press C button or...

Страница 11: ...ble tip against the forearm 3 Press the trigger button to activate the lancing device Hold the device against forearm and increase pressure until the blood sample size is sufficient Running A Blood Gl...

Страница 12: ...he cap 3 Pointing the lancing device toward a container for sharp or biohazard material slide the ejection button down to release the covered lancet into the container 2 Without touching the used lanc...

Страница 13: ...individual test result 4 To delete a test result press C button for more than 3 seconds and display shows dEL Then press power button to confirm the deletion 5 Press C button to keep reviewing the re...

Страница 14: ...n error message If you have any concerns please contact your local dealer Humidified Used strips Action Replace with a new strip Low power Action Replace with new batteries System fault Action Replace...

Страница 15: ...still the same try a control solution test and if the control solution test falls within the correct range please contact your healthcare professional The test result is lower than 1 1 mmol L 20 mg d...

Страница 16: ...test continues Action Relocate the meter to a location with temperature between 10 C 40 C 50 F 104 F The Lt and thermometer icon appears Temperature is too low outside the required range of 10 C 40 C...

Страница 17: ...mail info epsbio com tw Website http www epsbio com tw 0537 Reference American Diabetes Association Standards of Medical Care for Patients with Diabetes Mellitus Diabetes Care 25 2002 p S37 Obelis s...