 2-CHANNEL AMPLIFIER FEATURES

>>

MULTIPLE STAGES OF PROTECTION

Each channel is individually protected with operation mode indicated by bi-color LEDs on the front of the amplifier.  

These enable simple troubleshooting. If the circuitry determines that a channel must be shut down for protection due to 

a short, excessively low impedance or prolonged elevated temperatures, only the channel that is affected will be turned 

off.  The LED for the channel with a fault condition will turn red.  The other channel will continue to play and maintain a 

blue status LED. Once conditions return to normal for the channel with trouble, it will turn back on and status LED color 

will return to blue.

>>

INSTALLATION-FRIENDLY CONNECTIONS 

Each speaker channel features a gold-plated five-way binding post that can accommodate up to a 14 gauge stranded 

speaker wire.  The power cord is removable as well, facilitating fast and simple installations.  Inputs and outputs are 

high-quality RCA-type connectors.

>>

DURABLE AUDIOPHILE DESIGN

Episode™ amplifiers are built using superior quality components in sophisticated designs.  This delivers outstanding 

sound quality, performance and long-term reliability.

>>

RACK-MOUNTABLE

Each Episode amplifier includes an accessory package of rack ‘ears’ that may be attached to the amplifier by simply 

removing the four (4) side cover screws near the front of the amplifier and re-installing them through the rack ‘ear’.  The 

amplifier feet may be removed easily to facilitate clean rack mounting of the amplifier.  The amplifier chassis and rack 

ear are NOT designed to support anything other than the amplifier.  DO NOT stack components on top of the amplifier.  

It could damage the amplifier’s chassis and also cause excessive thermal conditions.  

>>

GAIN ADJUSTMENT

Volume/gain adjustment controls the overall volume of the speakers connected to the amplifier.

>>

LOW PASS FILTER ADJUSTMENT

When enabled the Low Pass Filter Adjustment allows the amplifier to be used with passive subwoofers such as those 

commonly installed in ceilings, walls and floors.  The control can be used in either stereo or bridged mode and is variable 

from 50Hz to 150Hz.

>>

BRIDGING

The power output of both channels can be combined to provide extra power when needed in certain areas. This is easily 

accomplished by flipping a single switch and connecting the speaker as indicated.

>>

POWER MODE

There are three choices for power modes with an Episode amplifier; ‘On’, ‘Auto’ and ‘Trigger’.  When the ‘On’ mode is 

enabled, your amplifier will remain on as long as it is plugged in to power and the main power switch on the front panel 

is switched to the on position.  If the ‘Trigger’ mode is chosen, the amplifier will turn on when a voltage of 3-30 volts 

(AC or DC) is applied and remains on the 3.5mm trigger input jack.  Tip is positive for this connection.  The ‘Auto’ mode 

works in a similar fashion.  Power will turn on whenever a minimal amount of signal is detected on the CH 1 or CH 2 

RCA jacks and off again when no signal is present after approximately 15 minutes.  Auto turn-on mode will not sense 

audio connected to the channel Line-In RCA jacks – use either On or Trigger mode when using these connections.

3

Содержание E-2100

Страница 1: ...LIFIER E 2100 STEREO POWER AMPLIFIER IMPORTANT SAFETY INSTRUCTIONS INTRODUCTION FEATURES INSTALLATION A FIRST STEPS B GETTING CONTROL C GETTING CONNECTED SETTING UP AMPLIFIER TROUBLESHOOTING SPECIFICA...

Страница 2: ...e caution when moving the cart apparatus combination to avoid injury from tip over 13 Unplug this apparatus during lightning storms or when unused for long periods of time 14 Refer all servicing to qu...

Страница 3: ...ding sound quality performance and long term reliability RACK MOUNTABLE Each Episode amplifier includes an accessory package of rack ears that may be attached to the amplifier by simply removing the f...

Страница 4: ...ough outputs allow inputs to be sent to other amplifiers Low pass frequency adjustments Volume Control Analog Inputs When using as a subwoofer amp use the supplied Y adapter cable as instructed Low pa...

Страница 5: ...s together for increased power Power on mode controls Choose among three different methods to turn on the amplifier Use the low voltage input and output when using the trigger mode Power connector Fus...

Страница 6: ...OUTPUTS Use 14 18 gauge stranded two conductor loudspeaker wire for all high level connections At each loudspeaker level connection ensure that at least 2 inches of each conductor are separated Strip...

Страница 7: ...ed switch into the bridged position Once in the bridged mode connect your speaker wire to the correct bridged position as labeled Do not connect more than one speaker to the bridged output without imp...

Страница 8: ...EPISODE TYPICAL INSTALLATION WITH SPEAKERS 8 STEREO SOURCE Set to STEREO Set to FLAT L R...

Страница 9: ...ESS 6 Amp Protection 6 5 4 3 2 1 one 1 one 2 one 3 one 4 one 5 one 6 Amp i ier EPISODE TYPICAL INSTALLATION WITH SPEAKER SELECTOR BOX 9 STEREO SOURCE Set to STEREO Set to FLAT L R...

Страница 10: ...EPISODE BRIDGED SUBWOOFER APPLICATION 10 SUBWOOFER OUT Set to BRIDGED Set to LOW PASS PASSIVE SUBWOOFER Y ADAPTER...

Страница 11: ...or a thermal issue Check wires and speaker connections for shorts or allow amplifier to cool The level adjustment on the channel is turned down Turn it to the right slowly to raise the volume Test th...

Страница 12: ...0 kHz 05 THD 20 Hz 20 kHz 8 08 THD 20 Hz 20 kHz 4 1 THD 20 Hz 20 kHz 8 16 5 w x 4 h including feet x 15 deep 21lbs 2 Year Limited Warranty Episode Amplifier Products have a 2 Year Limited Warranty Thi...

Отзывы: