![Epiphone Plexi SE PCB Скачать руководство пользователя страница 30](http://html1.mh-extra.com/html/epiphone/plexi-se-pcb/plexi-se-pcb_build-manual_2417863030.webp)
http://www.GuitarAmplifierPCBs.com
Plexi SE PCB Valve Junior Conversion
Version 2
Build Manual
23 August 2009
30 of 34
9.2 Power Up without Tubes
9.2.1 The First Power Up
Make sure you are working is a safe area free of any flammable
chemicals or vapors. An assembly error may result in the emission of
sparks.
The tubes should NOT be installed during the initial power up.
Plug the amplifier into a speaker cabinet. Match the speaker
impedance with the appropriate output jack. Failure to connect a
speaker will cause harm and eventual failure of the output transformer.
Verify the amp’s power switch is in the “Off” position. Insert the mains power
cord in the IEC mains connector.
Secure the black ground lead of your voltmeter to the chassis star ground lug.
Switch the power switch to the “ON” position. With your voltmeter, check the
following voltages. If a significant deviation from these readings is observed, turn
off the amp, unplug the mains power and investigate.
These measurements will read high since there is no load on the transformer.