CABLE ADJUSTMENTS
CAUTION:
After making any cable adjustment, pull
the handle using a light load and have someone make
sure that the cable is not derailed from a pulley or rub-
bing on a guard (see CABLE GUARDS on page 8).
INITIAL ADJUSTMENT
Top Weight Adjustment—
Tools required: Hammer, 1/8” punch, 3/16” roll pin
1. Lift the coupler cover from the top weight coupler.
2. Remove the roll pin from the top weight coupler
with an 1/8” punch and a hammer.
3. Align the hole in the cable coupling with the
appropriate adjustment hole in the top weight
coupler:
• If more slack is needed in the cable, align the
cable coupling with a higher hole.
• If less slack is needed in the cable, align the
cable coupling with a lower hole.
4. With the cable coupling aligned with the new
hole, drive a new roll pin into the top weight cou-
pler and cable coupler.
5. Lower the coupler cover over the top weight
coupler.
Adjustment Hole
Cable Coupling
Top Weight
Coupler
Coupler Cover
ADDITIONAL ADJUSTMENT
Tower Pulley Adjustment–
Tools required: 5/16" Allen wrench/hex key, 9/16"
open end wrench/spanner
1. Lift the top weight off the
weight stack and insert the
weight pin into the second
weight and the sixth hole
from the top of the weight
rod.
2. Loosen the locknut attach-
ing the pulley to the brack-
et in the top of the tower.
3. Move the pulley to the appropriate location in the
bracket:
• If more slack is needed in the cable, move the
pulley down.
• If less slack is needed in the cable, move the
pulley up.
4. Make sure that the cable guard is properly ori-
ented (see CABLE GUARDS on page 8) and
retighten the locknut attaching the pulley to the
bracket.
5. Lift the top weight and remove the weight pin.
Lower the top weight onto the second weight.
6. Readjust as necessary.
Locknut