2.   Turn fire feature on by turning on the electrical device used to power the fire feature.  
 
 

Sequence of Operation during Ignition 

 

-  Power is applied 

 

-  Hot Surface Igniter (Glow Plug) becomes hot and 4 seconds later the Gas Valve opens 

 

-  Within 10 seconds of power application Flame should be visible (at night only) 

 

 

 

Fire Feature Shutdown 

 

1.

 

Turn fire feature off by turning off the electrical device used to power the fire feature. 

 

 
 

 

 
 
 

Maintenance 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Prior to Each Use 

 

1.

 

Inspect for debris in Fire Feature – remove debris prior to use 

 

Semi-Annually  

 

1.

 

Visually inspect the Burner for debris/insect infestation (spider webs) 

 

Annually 

 

1.

 

Visually inspect Burner for excess corrosion due to heat and moisture. 

2.

 

Turn fire feature on to ensure proper operation.  

 

 

WARNING 

 

 

Maintenance should be done by a qualified service technician. 

The appliance should be inspected before use and at least annually by a qualified service technician. 

 

 

 

WARNING 

 

 

Ensure gas and power are shut off and appliance is cool before servicing. 

 

 

 

WARNING 

 

 

Any guard or protective device removed for servicing must be replaced prior to operation. 

 

 

 

WARNING 

 

 

If fire feature fails to turn off completely (small flames still visible)  

Turn off gas supply using the manual gas shutoff. 

 

Содержание Vulcan Fire Module VFM

Страница 1: ...t WARNING For Use with NATURAL or LP GAS Only NO SOLID FUELS TO BE USED WITH THIS SYSTEM INSTALLER Leave this manual with the appliance CONSUMER Retain this manual for future reference Installation mu...

Страница 2: ...z de l appariel 2 teindre toute flamme nue 3 Si l odeur persiste loignez vous de l appareil et appelez imm diatement le fournisseur de gaz ou le service d incendie AVERTISSEMENT Pour utilisation avec...

Страница 3: ...ir Mixer LP applications only Gas and Electrical Requirements Page 4 Clearance from Combustibles Page 4 Installation of Vulcan Fire Module Page 5 Acceptable Media for Fire Features Page 5 Operation Pa...

Страница 4: ...0 480 Volt AC Supplied 24 Volt AC Transformer compatible with all voltages listed above Read label on supplied transformer for proper connection information Recommended Wire Size 12 gauge wire for all...

Страница 5: ...ue to heat Vulcan Fire Module The illustration above shows the Vulcan Fire Module as it would look after installation is complete inside a small bowl 1 First step is to apply pipe dope to the gas rise...

Страница 6: ...to turning appliance on visually inspect fire feature to ensure debris such as leaves or other combustible material has not collected inside the feature which could burn and emit embers once the fire...

Страница 7: ...or to use Semi Annually 1 Visually inspect the Burner for debris insect infestation spider webs Annually 1 Visually inspect Burner for excess corrosion due to heat and moisture 2 Turn fire feature on...

Страница 8: ...t the Pilot flame with a handheld lighter If the flame ignites when you light it by hand go to the section below Electrical Current Electrical Current If you have determined that air in the gas line i...

Отзывы: