background image

 

 
 

 

TRIRON N Series 

         

——Modular MPPT Solar Charge Controller 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                         

 

   

 

User Manual 

Models: 

TRIRON1206N 

TRIRON2206N/TRIRON1210N 
TRIRON2210N/TRIRON3210N 
TRIRON4210N/TRIRON4215N 

   

 

Содержание TRIRON N Series

Страница 1: ...TRIRON N Series Modular MPPT Solar Charge Controller User Manual Models TRIRON1206N TRIRON2206N TRIRON1210N TRIRON2210N TRIRON3210N TRIRON4210N TRIRON4215N...

Страница 2: ......

Страница 3: ...ts inside the controller DO NOT disassemble or attempt to repair the controller Mount the controller indoors Prevent exposure to the elements and do not allow water to enter the controller Install the...

Страница 4: ......

Страница 5: ...9 2 2 PV Array Requirements 9 2 3 Wire Size 12 2 4 Mounting 13 3 Install the modules 16 4 Module Introduction 18 4 1 Display Module 18 4 1 1 Display Basic1 DB1 18 4 1 2 Display Standard1 DS1 19 4 1 3...

Страница 6: ...oad working modes 33 5 2 1 LCD setting 33 5 2 2 R485 communication setting 34 6 Protections Troubleshooting and Maintenance 37 6 1 Protection 37 6 2 Troubleshooting 38 6 3 Maintenance 40 7 Technical S...

Страница 7: ...a digital control circuit TRIRON N series controllers can effectively prolong the lifecycle of batteries significantly improve the system performance and support all around electronic protection funct...

Страница 8: ...l the inverter switch through the relay interface Provide 5VDC power through the dual USB output interface to charge electronic devices 1 2 Characteristics Mounting Hole 5mm PV Terminals Display Modul...

Страница 9: ...dule can be operated independently without any other modules Model System voltage Max PV open circuit voltage Rated charge discharge current Picture TRIRON1206N 12 24VDC 60V 10A TRIRON2206N 12 24VDC 6...

Страница 10: ...umption when the controller communicates with the inverter Display Standard 2 DS2 Indicators PV battery load working status Buttons View or set the parameters LCD PV display voltage current generated...

Страница 11: ...ia the LCD Relay interface Remotely control the inverter ON OFF Accessory 3 81 2P terminal Relay COM Slave RCS RS485 interface Connect to PC or phone View or change the controller parameters Relay int...

Страница 12: ...6 1 4 Designations of Controller Models EXAMPLE...

Страница 13: ...mote Meter MT50 MT50 can display various operating data and fault of the system The information can be displayed on a backlit LCD screen the buttons are easy to operate and the numeric display is read...

Страница 14: ...8...

Страница 15: ...s to secure cables and prevent them from swaying in mobile applications Lead acid battery and lithium battery are recommended other kinds please refer to the battery manufacturer Battery connection ma...

Страница 16: ...Max Best 12V 4 2 2 1 2 1 2 1 24V 4 3 2 2 2 2 2 2 System voltage 72 cell Voc 46V 96 cell Voc 62V Thin Film Module Voc 80V Max Best Max Best 12V 2 1 1 1 1 24V 2 1 1 1 1 NOTE The above parameter values a...

Страница 17: ...power to be higher than the rated power but if the PV power is three times greater than the rated power the controller will damaged WARNING If the PV array is reverse connected to the controller 1 5 t...

Страница 18: ...r to the table as below NOTE All PV modules in a given array are assumed to be identical Isc short circuit current amps Voc open circuit voltage Model Max PV input current Max PV wire size TRIRON1206N...

Страница 19: ...r install the controller in a sealed enclose with flooded batteries Do not install in a confined area where battery gas can accumulate WARNING Risk of electric shock When wiring the solar modules the...

Страница 20: ...n the reverse order NOTE While wiring the controller do not close the circuit breaker or fuse and make sure that the leads of and poles are connected correctly NOTE A fuse which current is 1 25 to 2 t...

Страница 21: ...3 2 Setting and Operation of Controller NOTE The RS 485 port is not SELV circuit it must have isolation between the port and the place where the end user can access directly Step 5 Powered on the con...

Страница 22: ...16 3 Install the modules...

Страница 23: ...17...

Страница 24: ...ging Green Fast Flashing 4Hz PV Over voltage Green On Solid Normal Green Slowly Flashing 1Hz Full Green Fast Flashing 4Hz Over voltage Orange On Solid Under voltage Red On Solid Over discharged Red Sl...

Страница 25: ...lashing 25 50 Indicators on solid 50 to 75 Green 100 Indicator slowly flashing 25 50 75 Indicators on solid 75 to 100 Green 25 50 75 100 Indicators on solid 100 Indicator is OFF Indicator is on Solid...

Страница 26: ...PV Over voltage Red On Solid Load ON Red OFF Load OFF 2 Button Mode Note Load ON OFF In load manual mode it can turn the load On Off of the load via the button Clear Fault Press the button Browsing M...

Страница 27: ...ttery capacity In Charging Battery Voltage Current Temperature Battery Type Load Load ON Load OFF Load Voltage Current Load mode 2 Browse interface 3 Load parameters Combination of the DS1 and RCM mod...

Страница 28: ...Step 1 Press the button and hold 5s under the PV power interface and the value is flashing Step 2 Press the button to clear the generated energy Switch the battery temperature unit Press the button an...

Страница 29: ...oad mode NOTE Please refer to 5 2 for the load working modes 4 1 3 Display Standard 2 DS2 1 Indicator Indicator Color Status Instruction Green On Solid PV connection normal but low voltage low irradia...

Страница 30: ...he button and hold 5s Setting the LCD cycle time Press the button BATT browsing interface Cursor displacement during setting Press the button and hold 5s Setting the battery type battery capacity leve...

Страница 31: ...Generated Energy 2 Battery parameters Display Voltage Current Temperature Battery capacity level 3 Load parameters Combination of the DS2 and RCM modules To connect the system with the inverter refer...

Страница 32: ...or button to choose the battery type Step 4 Press the button to confirm the battery type NOTE Please refer to chapter 5 1 for the battery control voltage when the battery type is User 2 Battery capaci...

Страница 33: ...ress the or button to set the temperature units Step 5 Press the button to confirm the parameters 4 LCD cycle time NOTE The LCD cycle default time is 2s the setting time range is 0 20s Operation Step...

Страница 34: ...tion USB output interface Standard USB 5VDC 2 2A Total Yes RS485 com interface RJ45 5VDC 100mA Yes Relay interface 3 81 2P 30VDC 1A NO 4 2 2 Double USB USB1 USB output interface Charging for phone pad...

Страница 35: ...on of the RCM and DS1 DS2 modules the information of the inverter to be supplied by our company can be displayed by the DS1 DS2 module See the following figure Relay interface It shall connect the con...

Страница 36: ...a combination of the RCS and DS1 DS2 modules the information of the inverter to be supplied by our company can be displayed by the DS1 DS2 module Relay interface It shall connect the controller s rela...

Страница 37: ...Voltage Sealed Gel Flooded User Over Voltage Disconnect Voltage 16 0V 16 0V 16 0V 9 17V Charging Limit Voltage 15 0V 15 0V 15 0V 9 17V Over Voltage Reconnect Voltage 15 0V 15 0V 15 0V 9 17V Equalize C...

Страница 38: ...r Download software User for lithium battery http www epever com Android APP for the Li Battery Solar Charge Controller 3 Setting the control voltage value The following rules must be observed when mo...

Страница 39: ...ge Reconnect Voltage Low Voltage Disconnect Voltage Discharging Limit Voltage Under Voltage Warning Reconnect Voltage Under Voltage Warning Voltage Discharging Limit Voltage Boost Reconnect Charging v...

Страница 40: ...202 Load will be on for 2 hours before sunrise 103 113 Load will be on for 3 13 hours since sunset 203 213 Load will be on for 3 13 hours before sunrise 114 Load will be on for 14 hours since sunset 2...

Страница 41: ...ON Timer Time Control Control the load ON OFF time through setting the real time clock 2 Load working mode settings 1 PC setting Connection Download software http www epever com PC Software for the So...

Страница 42: ...oftware setting Download software http www epever com Android APP for the Solar Charge Controller 3 MT50 Setting NOTE For detailed setting methods please refer to the instructions or contact after sal...

Страница 43: ...temperature exceeds 65 C and begins working when its temperature is below 55 C Lithium Battery Low Temperature When the temperature detected by the optional temperature sensor is lower than the Low Te...

Страница 44: ...troller DB1 Charging indicator Green fast flashing Battery over voltage Check if battery voltage is higher than OVD over voltage disconnect voltage and disconnect the PV DS1 DS2 Charging indicator Gre...

Страница 45: ...e reduce the number of electric equipments Restart the controller wait for one night day cycle night time 3 hours Load Short Circuit Check carefully loads connection clear the fault Restart the contro...

Страница 46: ...confirm that LED is consistent with required Pay attention to any troubleshooting or error indication Take corrective action if necessary Confirm that all the system components are ground connected t...

Страница 47: ...260W 24V 260W 12V 520W 24V 130W 12V 260W 24V 260W 12V 520W 24V 390W 12V 780W 24V 520W 12V 1040W 24V 520W 12V 1040W 24V Self consumption 14mA 12V 15mA 24V Discharge circuit voltage drop 0 18V Temperatu...

Страница 48: ...06N TRIRON1210N TRIRON2206N TRIRON2210N TRIRON3210N TRIRON4210N TRIRON4215N Dimension 135 180 8 47 3mm 150 216 56 7mm 158 238 3 62 7mm 183 256 8 66 7mm Mounting dimension 126 150mm 141 170mm 158 200mm...

Страница 49: ...12V 2 Solar Module MPP Voltage 34V Nominal System Voltage 24V 88 00 89 00 90 00 91 00 92 00 93 00 94 00 95 00 96 00 97 00 30 100 130 150 200 Conversion Efficiency Charging Power W 12V Conversion Effi...

Страница 50: ...Voltage 24V 91 00 92 00 93 00 94 00 95 00 96 00 97 00 98 00 30 100 150 200 260 300 Conversion Efficiency Charging Power W 12V Conversion Efficiency Curves 17V 34V 95 00 95 50 96 00 96 50 97 00 97 50 9...

Страница 51: ...tem Voltage 24V 85 00 87 00 89 00 91 00 93 00 95 00 97 00 99 00 30 100 150 200 260 300 Conversion Efficiency Charging Power W 12V Conversion Efficiency Curves 17V 34V 51V 88 00 90 00 92 00 94 00 96 00...

Страница 52: ...4V 85 00 87 00 89 00 91 00 93 00 95 00 97 00 99 00 30 100 150 200 300 390 500 Conversion Efficiency Charging Power W 12V Conversion Efficiency Curves 17V 34V 51V 89 00 90 00 91 00 92 00 93 00 94 00 95...

Страница 53: ...ltage 24V 88 00 90 00 92 00 94 00 96 00 98 00 100 00 50 100 150 200 300 400 520 600 Conversion Efficiency Charging Power W 12V Conversion Efficiency Curves 17V 34V 51V 88 00 90 00 92 00 94 00 96 00 98...

Страница 54: ...48 Model TRIRON4215N 1 Solar Module MPP Voltage 16 5V 33V 66V Nominal System Voltage 12V 2 Solar Module MPP Voltage 33V 66V 98V Nominal System Voltage 24V...

Страница 55: ...49 Annex II Dimensions TRIRON1206N TRIRON1210N Unit mm...

Страница 56: ...50 TRIRON2206N TRIRON2210N Unit mm...

Страница 57: ...51 TRIRON3210N Unit mm...

Страница 58: ...52 TRIRON4210N TRIRON4215N Unit mm Any changes without prior notice Version number 1 2...

Страница 59: ......

Страница 60: ...BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 86 10 82894112 82894962 Fax 86 10 82894882 E mail info epsolarpv com Website http www epsolarpv com http www epever com...