background image

 

 
 

 

Tracer-AN Series 

                       

——MPPT Solar Charge Controller 

 
 
 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

                                                         

 

   

 

 

User Manual 

Models: 

Tracer1206AN/Tracer2206AN 
Tracer1210AN/Tracer2210AN 
Tracer3210AN/Tracer4210AN   

 

 

Содержание Tracer1206AN

Страница 1: ...Tracer AN Series MPPT Solar Charge Controller User Manual Models Tracer1206AN Tracer2206AN Tracer1210AN Tracer2210AN Tracer3210AN Tracer4210AN...

Страница 2: ......

Страница 3: ...ts inside the controller DO NOT disassemble or attempt to repair the controller Mount the controller indoors Prevent exposure to the elements and do not allow water to enter the controller Install the...

Страница 4: ...Instructions 7 2 1 General Installation Notes 7 2 2 PV Array Requirements 7 2 3 Wire Size 10 2 4 Mounting 11 3 Operation 14 3 1 Button 14 3 2 Interface 14 3 3 Setting 16 3 4 Accessories optional 21 4...

Страница 5: ...system performance and support all around electronic protection functions including overcharging and over discharging protection to minimize damages to components of the system caused by incorrect in...

Страница 6: ...et the parameters via mobile phone APP or PC software Full load operation without any drop in capacity within the range of working environment temperature Extensive electronic protection 1 2 Character...

Страница 7: ...of the array The tracking process is fully automatic and does not need user adjustment As the Figure 1 2 the curve is also the characteristic curve of the array the MPPT technology will boost the batt...

Страница 8: ...Power Point As the below Figure 1 3 shows Figure 1 3 Mutil MPP Curve If the program works improperly after appearing Multi MPP the system will not work on the real max power point which may waste mos...

Страница 9: ...ost These two stages are not carried out constantly in a full charge process to avoid too much gas precipitation or overheating of battery Boost Charging The Boost stage maintain 2 hours in default us...

Страница 10: ...constant voltage controller will accumulate and calculate the time of constant voltage working When the accumulated time reach to 3 hours the charging mode will turn to Float Charging 2 If the control...

Страница 11: ...s to secure cables and prevent them from swaying in mobile applications Lead acid battery and lithium battery are recommended other kinds please refer to the battery manufacturer Battery connection ma...

Страница 12: ...Best Max Best 12V 2 1 1 1 1 24V 2 1 1 1 1 NOTE The above parameter values are calculated under standard test conditions STC Standard Test Condition Irradiance 1000W m2 Module Temperature 25 Air Mass1...

Страница 13: ...xceeds the rated charging power of controller then the charging time as per the rated power will be prolonged so that more energy can be obtained for charging the battery However in the practical appl...

Страница 14: ...ay are assumed to be identical Isc short circuit current amps Voc open circuit voltage Model Max PV input current Max PV wire size Tracer1206AN Tracer1210AN 10A 4mm2 12AWG Tracer2206AN Tracer2210AN 20...

Страница 15: ...h flooded batteries Do not install in a confined area where battery gas can accumulate WARNING Risk of electric shock When wiring the solar modules the PV array can produce open circuit voltages in ex...

Страница 16: ...ION A fuse which current is 1 25 to 2 times the rated current of the controller must be installed on the battery side with a distance from the battery not greater than 150 mm CAUTION If the controller...

Страница 17: ...CAUTION If the remote temperature sensor is not connected to the controller the default setting for battery charging or discharging temperature is 25 C without temperature compensation Connect the ac...

Страница 18: ...Press the ENTER button Browsing Mode Press the SELECT button Setting Mode Press the ENTER button and hold on 5s to enter the setting mode Press the SELECT button to set the parameters Press the ENTER...

Страница 19: ...el shows empty battery frame blink fault icon blink Battery over voltage Battery level shows full battery frame blink fault icon blink Battery over temperature Battery level shows current value batter...

Страница 20: ...the ENTER button and hold 5s under the PV power interface and the value is flashing Step 2 Press the ENTER button to clear the generated energy 2 Switch the battery temperature unit Press the ENTER b...

Страница 21: ...ge Control Parameters Below parameters are in 12V system at 25 C please double the values in 24V system Battery type Voltage Sealed Gel Flooded User Over Voltage Disconnect Voltage 16 0V 16 0V 16 0V 9...

Страница 22: ...3 Setting the control voltage value The following rules must be observed when modifying the parameter values in User for lead acid battery Over Voltage Disconnect Voltage Charging Limit Voltage Equal...

Страница 23: ...the deviation is higher than 0 2V the manufacturer will assume no liability for any system malfunction caused by this 4 Local load mode Operation Step1 Press the ENTER button and hold on 5s under the...

Страница 24: ...be disabled and display 2 n Load working mode settings 1 PC setting Connection Download software http www epever com PC Software for the Solar Charge Controller 2 APP software setting Download softwa...

Страница 25: ...mote Meter MT50 MT50 can display various operating data and fault of the system The information can be displayed on a backlit LCD screen the buttons are easy to operate and the numeric display is read...

Страница 26: ...22...

Страница 27: ...e battery temperature through an external temperature sensor The controller stops working when its temperature exceeds 65 C and begins working when its temperature is below 55 C Lithium Battery Low Te...

Страница 28: ...hen the battery voltage is restored to or above LVR low voltage reconnect voltage the load will recover Battery Overheating The controller will automatically turn the system off But while the temperat...

Страница 29: ...that all the system components are ground connected tightly and correctly Confirm that all the terminals have no corrosion insulation damaged high temperature or burnt discolored sign tighten termina...

Страница 30: ...12mA Discharge circuit voltage drop 0 23V Temperature compensate coefficient 3mV 2V Default Grounding Common negative RS485 interface 5VDC 100mA LCD backlight time 60S Default When a lead acid batter...

Страница 31: ...10AN Dimension 172x139 x 44mm 220x154x 52mm 228x164x55mm 252x180x63mm Mounting dimension 130x130mm 170x145mm 170x164mm 210x171mm Mounting hole size 5mm Terminal 12AWG 4mm2 6AWG 16mm2 6AWG 16mm2 6AWG 1...

Страница 32: ...nversion Efficiency Curves Illumination Intensity 1000W m 2 Temp 25 C Model Tracer1206AN 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V Nominal System...

Страница 33: ...29 Model Tracer1210AN 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 51V 68V Nominal System Voltage 24V...

Страница 34: ...30 Model Tracer2206AN 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V Nominal System Voltage 24V...

Страница 35: ...31 Model Tracer2210AN 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V 68V Nominal System Voltage 24V...

Страница 36: ...32 Model Tracer3210AN 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V 68V Nominal System Voltage 24V...

Страница 37: ...33 Model Tracer4210AN 1 Solar Module MPP Voltage 17V 34V Nominal System Voltage 12V 2 Solar Module MPP Voltage 34V 45V 68V Nominal System Voltage 24V...

Страница 38: ...34 Annex II Dimensions Tracer1206 1210AN Unit mm...

Страница 39: ...35 Tracer2206AN 2210AN Unit mm...

Страница 40: ...36 Tracer3210AN Unit mm...

Страница 41: ...37 Tracer4210AN Unit mm Any changes without prior notice Version number 1 0...

Страница 42: ......

Страница 43: ......

Страница 44: ...BEIJING EPSOLAR TECHNOLOGY CO LTD Tel 86 10 82894112 82894962 Fax 86 10 82894882 E mail info epsolarpv com Website http www epsolarpv com http www epever com...