13
of PV array, battery and load can also be ungrounded, but the grounding terminal on
its shell must be grounded, which may effectively shield the electromagnetic
interference from the outside, and prevent some electric shock to human body due to
the electrification of the shell.
CAUTION:
For common-negative system, such as motorhome, it is
recommended to use a common-negative controller; but if in the
common-negative system, some common-positive equipment are used,
and the positive electrode is grounded, the controller may be damaged.
Step 4
:
Connect
accessories
Connect the remote temperature sensor cable (model: RTS300R47K3.81A)
(
Model:RT-MF58R47K3.81A
)
(
Model:RTS300R47K3.81A
)
Connect one end of the remote temperature sensor cable
to the interface
③
and place the other end close to the battery.
CAUTION:
If the remote temperature sensor is not connected to the
controller,, the default setting for battery charging or discharging
temperature is 25 °C without temperature compensation.
Connect the accessories for RS485 communication
Refer to chaper
3.3
“Setting”
CAUTION:
If the remote temperature sensor is not connected to the
controller,, the default setting for battery charging or discharging
temperature is 25 °C without temperature compensation.
Step 5
:
Powered on the controller
Closing the battery fuse will switch on the controller. Then check the status of the
battery indicator (the controller is operating normally when the indicator is lit in green).
Close the fuse and circuit breaker of the load and PV array. Then the system will be
operating in the preprogrammed mode.
CAUTION:
If the controller is not operating properly or the battery indicator
on the controller shows an abnormality, please refer to
4.2
“
Troubleshooting
”.
Temperature Sensor
Remote Temperature Sensor
Cable (Optional)
Содержание Tracer1206AN
Страница 2: ......
Страница 26: ...22...
Страница 38: ...34 Annex II Dimensions Tracer1206 1210AN Unit mm...
Страница 39: ...35 Tracer2206AN 2210AN Unit mm...
Страница 40: ...36 Tracer3210AN Unit mm...
Страница 41: ...37 Tracer4210AN Unit mm Any changes without prior notice Version number 1 0...
Страница 42: ......
Страница 43: ......