temperature protection 

lower  than  the  Low  Temperature  Protection  Threshold  (LTPT),  the 

controller  stops  charging  and  discharging  automatically.  When  the 

detected  temperature  exceeds the LTPT, the controller resumes work 

automatically. (The LTPT is 0 °C by default and can be set within 10 ~ 

-40 °C. Detail settings refer to the LTPT V1.0.) 

Controller Overheating

 

An internal temperature sensor can detect the internal temperature of 

the  controller.  The  controller  stops  working  when  the  internal 

temperature  exceeds  85

  and  resumes  work  when  the  internal 

temperature is below 75

TVS high voltage 

transients protection

 

The  controller's  internal  circuitry  is  designed  with  Transient  Voltage 

Suppressors (TVS), which can only protect against high-voltage surge 

pulses with less energy. Suppose the controller is to be used in an area 

with frequent lightning strikes. In that case, it is recommended to install 

an external surge arrester.

 

 When the control's internal temperature is 81

, the reducing power charging mode is turned on, reducing 

the charging power by 5%,10%,20%, and 40% for every increase of 1

. If the internal temperature is greater 

than 85

, the controller stops charging. When the internal temperature is not more than 75ºC, the controller 

will resume charge as per the rated power. 

For example, Tracer10420AN 48V system:                                                                                 

 

 

4.2 Troubleshooting 

Faults 

Faults 

Solutions 

Charging  LED  is  OFF  during 

daytime  when  sunshine  falls  on  PV 

array properly 

PV array 

open-circuit 

Confirm whether  the connection of 

the PV array is correct and tight 

0

1000

2000

3000

4000

5000

6000

75 76 77 78 79 80 81 82 83 84 85 86 87 88 89 90 91

C

ha
rge

pow

e

W

Internal temperature

Reduce charging power  mode

Power W

Содержание Tracer10415AN

Страница 1: ...MPPT Solar Charge Controller User Manual Model Tracer6210AN Tracer5415AN Tracer6415AN Tracer8415AN Tracer10415AN Tracer5420AN Tracer6420AN Tracer8420AN Tracer10420AN...

Страница 2: ......

Страница 3: ...stallation 5 2 1 Attentions 5 2 2 Requirements for the PV array 5 2 3 Wire size 7 2 4 Dry contact instruction 8 2 5 Mounting 9 3 Operation 13 3 1 Indicator 13 3 2 Buttons 13 3 3 LCD Display 14 3 4 Set...

Страница 4: ......

Страница 5: ...ry fuse breakers before controller installation and adjustment Power connections must remain tight to avoid excessive heating from a loose connection The entire system should be installed by professio...

Страница 6: ...id power system easily Comprehensive electronic protections including overcharging over discharging and PV reverse polarity protection effectively ensure a more reliable and durable solar system opera...

Страница 7: ...battery cables voltage drop Isolated RS485 communication ports Modbus protocol 5V 200mA RS485 communication ports with short circuit protection Support remote monitoring and parameters setting via th...

Страница 8: ...when connecting multiple controllers in parallel RS485 ports are for cascaded use 4 Connect an RBVS Remote Battery Voltage Sensor to detect accurate battery voltage The sampling distance is no longer...

Страница 9: ...connector may be wired to another battery or a bank of batteries The following instructions refer to a singular battery Still it is implied that the battery connection can be made to either one batter...

Страница 10: ...1 24V 3 2 2 1 1 48V 3 2 2 2 1 IMPORTANT The above parameters are calculated under standard test conditions STC Standard Test Condition Module Temperature 25 Air Mass1 5 Irradiance 1000W m2 Tracer5420...

Страница 11: ...For max PV input current and max PV wire size please refer to the table below Model Max PV input current Max PV wire size Tracer5415AN Tracer5420AN 50A 16mm2 6AWG Tracer6210AN Tracer6415AN Tracer6420...

Страница 12: ...rator VBAT VON Stop the Utility Generator VBAT VOFF CAUTION Before starting or stopping the Utility Generator via the Utility Generator dry contact you shall set the switch to the ON position The VON...

Страница 13: ...ules the PV array can produce a high open circuit voltage so disconnect the breaker before wiring and be careful Tracer AN series controllers have no battery reverse protection Do not reverse the batt...

Страница 14: ...uring the wiring Otherwise the controller may be damaged CAUTION During the wiring please do not connect the circuit breaker or fuse Ensure that the electrode polarity is correctly connected A fuse wh...

Страница 15: ...11 controller s Load dry contact to the inverter s start stop dry contact Otherwise the controller may be damaged Single controller Connection in parallel...

Страница 16: ...nect the remote temperature sensor cable Model RTS300R47K3 81A Connect the remote temperature sensor cable to the interface and place the other end close to the battery CAUTION Suppose the remote temp...

Страница 17: ...w PV voltage Green Slowly flashing 1Hz Normal charging Green Fast flashing 4Hz PV over voltage IMPORTANT The fault indicator refers to chapter 3 3 LCD Display 3 2 Buttons Modes Note Load dry contact I...

Страница 18: ...nd generate energy Battery Battery capacity In Charging Battery Voltage Current Temperature Battery type Load Load dry contact connected Load dry contact disconnected 2 Browse interface IMPORTANT When...

Страница 19: ...nk System voltage error Red slowly flashing Fast flashing in green Battery level shows current value battery frame blink and fault icon blink 3 4 Setting 1 Clear the generated energy In the PV power i...

Страница 20: ...ium battery type must be set through the PC or APP Set the battery type via the PC software or APP software PC software Connect the controller and the PC through the USB to the RS485 converter and set...

Страница 21: ...6V 12 6V 9 17V Under voltage warning reconnect voltage 12 2V 12 2V 12 2V 9 17V Under voltage warning voltage 12 0V 12 0V 12 0V 9 17V Low voltage disconnect voltage 11 1V 11 1V 11 1V 9 17V Discharging...

Страница 22: ...ltage 10 6V 9 3V 9 17V The following rules must be observed when modifying the parameter values in User for a lithium battery A Over Voltage Disconnect Voltage Over Charging Protection Voltage Protect...

Страница 23: ...ower is 1 5 times the controller s rated power the controller may be damaged Night reverse charging protection Prevent the battery from discharging to the PV module at night Battery over voltage prote...

Страница 24: ...igh voltage surge pulses with less energy Suppose the controller is to be used in an area with frequent lightning strikes In that case it is recommended to install an external surge arrester When the...

Страница 25: ...e best performance Make sure no block on airflow around the controller Clear up any dirt and fragments on the radiator Check all the naked wires to ensure insulation is not damaged by sun exposure fri...

Страница 26: ...fficiency 99 5 Max conversion efficiency 98 3 Full load efficiency 97 8 97 1 Temperature compensate coefficient 3mV 2V Default Self consumption 98mA 12V 60mA 24V 50mA 36V 46mA 48V Grounding Common neg...

Страница 27: ...Self consumption 98mA 12V 60mA 24V Grounding type Common negative grounding Dry contact Rated value 5A 30VDC Max value 0 5A 60VDC Communication method RS485 5VDC 200mA Two RJ45 ports in parallel LCD...

Страница 28: ...ing Dry contact Rated value 5A 30VDC Max value 0 5A 60VDC Communication method RS485 5VDC 200mA Two RJ45 ports in parallel LCD backlight time Default 60S Range 0 999S 0S the backlight is ON all the ti...

Страница 29: ...he time Mechanical parameters Dimension L x W x H 394 240 134mm Mounting size L x W 300 228mm Mounting hole size 7mm Wire size 2AWG 35mm2 Recommended cable 4AWG 25mm2 Net Weight 6 1kg When connecting...

Страница 30: ...W 300 230mm Mounting hole size 7mm Wire size 2AWG 35mm2 Recommended cable 2AWG 35mm2 Net Weight 7 4kg When connecting the controller to external devices only one of the communication ports is used wh...

Страница 31: ...27 Appendix 1 Dimensions Unit mm Tracer5415 5420AN...

Страница 32: ...28 Tracer6210AN...

Страница 33: ...29 Tracer6415 6420AN...

Страница 34: ...30 Tracer8415 8420AN...

Страница 35: ...31 Tracer10415 10420AN Any changes without prior notice Version number V3 4...

Страница 36: ...HUIZHOU EPEVER TECHNOLOGY CO LTD Tel 86 752 3889706 E mail info epever com Website www epever com...

Отзывы: