![Epever iTracer IT4415ND Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/epever/itracer-it4415nd/itracer-it4415nd_user-manual_2417290010.webp)
6
Figure 1-3 Mutil-MPP Curve
If the program works improperly after appearing Multi-MPP, the system will not
work on the real max. power point, which may waste most solar energy
resources and seriously affect the normal operation of the system. The typical
MPPT algorithm, designed by our company, can track the real MPP quickly
and accurately, improve the utilization rate of the array and avoid the waste of
resources.
1.5 Battery Charging Stage
The controller has a 3 stages battery charging algorithm (Bulk Charging,
Constant Charging and Float Charging) for rapid, efficient, and safe battery
charging.
Figure 1-4 Battery changing stage
Curve
Содержание iTracer IT4415ND
Страница 1: ...iTracer ND series MPPT Solar Charge Controller User Manual Models IT4415ND IT6415ND...
Страница 2: ......
Страница 38: ...34 Figure6 2 Real Time Monitoring Figure6 3 Control Parameter...
Страница 45: ...41 Annex II Dimensions IT4415ND Dimensions Unit mm...
Страница 47: ......