14
Step 1
:
Long press
to into the setting interface;
Step2
:
Press
or
to select the setting item;
Step3
:
Long press
and the digit is flashing to set the parameter;
Step4
:
Long press
to enter the parameter;
Step5
:
Press
and
to exit the setting interface.
Display
Parameter
Default
Setting range
Output voltage class
①
220Vac
220Vac/230Vac
110Vac
110Vac/120Vac
Output frequency
class
①
50Hz
50Hz/60Hz
LCD backlight time
30s
30s/60s/100s(On Solid)
Low voltage
disconnect voltage
②
10.8V
10.5V
~
11.3V;
step size 0.1V
Low voltage
reconnect voltage
②
12.5V
12.0V
~
13.0V;
step size 0.1V
Over voltage
reconnect voltage
②
14.5V
14.0V
~
15.0V;
step size 0.1V
Over voltage
disconnect voltage
③
16V
15.5V
~
16.2V;
step size 0.1V
①
The inverter must be restarted after change the parameters.
②
4-6 parameters are in the 12V system at 25 ºC; please double the values in the24V
system and quadruple the values in the48V system.
③
The user-defined range of 24V system is 31~32.2V, and the user-defined range of
24V system is for the 7 parameter.
5.6Fault code
Fault code
Fault
Buzzer
Internal over temperature
Heat sink over temperature
Sounds five
times
Input overvoltage
Input low voltage
Output short circuit
Output overload
Output voltage is abnormal