![Epelsa ECO MULTIFUNCTION Скачать руководство пользователя страница 18](http://html1.mh-extra.com/html/epelsa/eco-multifunction/eco-multifunction_user-manual_2417276018.webp)
17
GBU-ECO-MF-V01
Enter the unit weight with the numeric keys and confirm by pressing the
key.
The unit performs the same function explained in the previous section.
NOTE:
The unit weight is reduced to a thousandth. In other words, 1.000 does not
mean 1 kg, but 1 gram. The minimum unit weight for all capacities is limited to 1 g. The scale has a
resolution of 60000 internal points and a full-scale error (Em):
Em=Sm*100 / 2*Pdm
Where:
Em = error converted to % weight.
Sm = scale step.
Pdm = weight shown on part display.
Always provided that the parts have an uniform shape and the same weight.
7.3.
PART COUNTING BY COMPARISON
With a sample of the parts on the platform (with a total weight, for
example, of 1.200 kg), press the key:
Enter the number of parts in the sample placed on the platform and press the key
(for example, 10):
0
QTY
PARTS
Max 15 kg
Min 100 g
e= 5 g
I I I
kg
kg
Pcs
T
PT