C
Charging indicator(1)
NO.
LED status
Phenomenon
Cause
Remedy
Description
1
Red light is on
Trouble free
/
Charging
2
Green light is on
Trouble free
/
End of charging
3
No
indicator light
Current/
voltage
changes
Indicator failure Return to factory
maintenance
Charger failure
4
No change in
current/voltage
The power input
line is in good
contact with the
socket and the
charger
Charger
failure,return
to factory
maintenance
Charger failure
5
Red light flashes
The power input
cable is not in
good contact
with the socket
Check if the input
power line is in
good contact
6
Yellow light is on
Storage
battery fails.
(battery reverse
connection)
Eliminate battery
failure
7
Storage battery
fails.(battery is
not connected)
Eliminate battery
failure
8
Yellow light flashes
Ambient
temperature is
too high
Ambient
temperaturedrops
to normal
9
Storage battery
voltage exceeds
32.5V
(
65V for
WPL201)
Eliminate battery
failure
10
Charger failure
return to factory
maintenance