REV. 12/2019
7
C
Common Problems and Solutions
During the use and maintenance of the lithium-ion battery, the battery or battery system may
have one or more of the following abnormal conditions, please organize the professional
engineers and technicians to perform the necessary processing according to the instructions
in this manual; if you have any questions about the status or solutions, please contact ep
dealer or after-sales service department of the company to obtain professional technical
support.
If the battery is found to have abnormal mechanical characteristics such as swelling, cracked
casing, melted casing, and distortion of the casing before and during installation, stop using
the battery immediately, place it in open and well-ventilated space, and contact the after-
sales service.
If abnormalities such as looseness, cracks, cracks in the insulation layer, burn marks, etc.
of the battery's pole pressing bolts, conductive strips, main circuit wires and connectors are
found before and during the installation, stop using the battery immediately, check the reason
for analysis and give it a fix;
If the polarity of the positive and negative terminals of the battery is found not match the
polarity identification before installation, please stop using the battery immediately and
contact the after-sales service department to replace the battery or obtain other solutions;
If there is fire or smoke happens to the battery, move it to the open air immediately, evacuate
people in time, and pour a large amount of cold water onto the battery to cool it down and put
out the fire.
If the battery is found to emit smoke before and during installation, immediately stop using
the battery and bury it with sand, and notify the after-sales service department of the
company for record and obtain technical support
;
3.3.6
•
•
•
•
•
Disposal of Used Battery Packs
To prevent environmental pollution, the battery should be sent to a local recycling center or
special organization.
3.3.7
Storage
We recommend that batteries are stored at a height between 60 and 120 cm.
•Store the battery in a dry place at a temperature between 0 and 40° to preserve its
service life. This area must not be hermetically sealed to allow air renewal;
•Check the battery charge level regularly. Do this at least every three months to
maintainthe charge level above 30%. Recharge the battery if necessary.