60
Error Message
Possible cause
Fault elimination
Error
Error text
206
INIT VMN
HIGH
Before closing the LC, the software
checks the power-bridge voltage without
driving it. The software expects the
voltage to be in a “steady state” value. If it
is too high, this alarm occurs. The
hexadecimal value “XX” identifies the
faulty phase:
81: phase U
82: phase V
83: phase W
1- Check the motor power cables.
2- Check the impedance between
U, V and W terminals and -B
terminal of the controller.
3- Check the motor leakage to
truck frame.
4- If the motor connections are OK
and there are no external low
impedance paths, the problem is
inside the controller. Replace it.
207
INIT VMN
LOW
Before closing the LC, the software
checks the power-bridge voltage without
driving it. The software expects the
voltage to be in a “steady state” value. If it
is too low, this alarm occurs. The
hexadecimal value “XX” identifies the
faulty phase:
01: phase U
02: phase V
03: phase W
1- Check the motor power cables.
2- Check the impedance between
U, V and W terminals and -B
terminal of the controller.
3- Check the motor leakage to
truck frame.
4- If the motor connections are OK
and there are no external low
impedance paths, the problem is
inside the controller. Replace it.
208
EEPROM
KO
the connection of the EEPROM is not ok
This type of fault is related to
internal components. Replace the
logic board.
209
PARAM
RESTORE
The controller has restored the default
settings. If a CLEAR EEPROM has been
made before the last key re-cycle, this
warning informs you that EEPROM was
correctly cleared.
1- A travel demand or a pump
request does cancel the alarm.
2- If the alarm appears at key-on
without any CLEAR EEPROM
performed, replace the controller.
210
WRONG
RAM MEM.
The algorithm implemented to check the
main RAM registers finds wrong contents:
the register is “dirty”. This alarm inhibits
the machine operations.
Try to switch the key off and then
on again, if the alarm is still
present replace the logic board.